Laserfiche WebLink
• Would not replace any affordable residential units. <br /> Therefore, the proposed project also meets Criterion #3. <br /> Based on the screening criteria, as well as the significance criteria presented in Chapter 1 of <br /> the Traffic Study, the project's impact on VMT is expected to be less-than-significant and no <br /> mitigation is required. <br /> Holiday Traffic <br /> The traffic study noted that because the project is located near a regional shopping mall, there <br /> are periods in late November and December when traffic conditions would be different than <br /> described in the traffic study. Generally, vehicle trips increase during the PM commute hour for <br /> some traffic movements around retail centers beginning in Thanksgiving and peaking just <br /> before Christmas. However, holiday season travel patterns occur for a relatively few numbers <br /> of days each year and are considered atypical. The traffic engineering profession generally <br /> discourages data collection during atypical periods because it is uneconomical to construct <br /> physical improvements to accommodate seasonal traffic increases. For this reason, the <br /> transportation infrastructure and land use impacts of new projects are commonly analyzed <br /> during the non-holiday period, when travel conditions are more representative of the entire <br /> year. <br /> Parking <br /> For Phase I, the applicant is proposing to repurpose and utilize 483 existing surface level <br /> parking spaces on the subject site. The proposed parking ratio is approximately one space per <br /> 313 gross sq. ft (consistent with the Workday project). At buildout, if the proposed six-level <br /> parking garage and surface parking is constructed, the proposed parking ratio is approximately <br /> one space per 313 gross sq. ft (consistent with the Workday project); equivalent to 3.3 spaces <br /> per 1 ,000 square feet. <br /> Being a PUD, parking requirements are determined on a case-by-case basis. The proposed <br /> parking ratios for Phase I and buildout are slightly less than the PMC's office parking <br /> requirement (in non-PUD zones) of one space per 300 gross sq. ft (equivalent to 3.3 spaces <br /> per 1,000 square feet). Given the proximity to the West Dublin / Pleasanton BART station and <br /> two bus stops, and the various measures the applicant will implement to promote alternative <br /> commutes (e.g., installing bicycle racks/storage, designating carpool spaces, providing <br /> incentive-based programs for employees, etc.), staff believes many employees will not drive to <br /> work. Therefore, staff can support the small, 1.4 percent (18 space), reduction to the typical <br /> PMC parking requirement office uses, reflecting the sort of flexibility that is the intent of the <br /> PUD zone. To ensure parking is not an issue, staff is also recommending a condition of <br /> approval that if operation of the proposed use results in conflicts/complaints pertaining to <br /> parking and/or traffic/circulation, the applicant would be required to provide existing parking <br /> and employee counts to the City's Traffic Engineer for review. If necessary, the City's Traffic <br /> Engineer may require site and/or operational modifications to the use to mitigate any impacts. <br /> PUD-139 and P20-0973, 10x Genomics, Inc. Planning Commission <br /> 26 of 32 <br />ion <br /> 25 of 32 <br />ection of two or more major bus routes with a frequency of service interval of 15 <br /> minutes or less during the morning and afternoon peak commute periods. <br /> 6 A high-quality transit corridor is a corridor with fixed route bus service with service intervals no longer than 15 <br /> minutes during peak commute hours. <br /> PUD-139 and P20-0973, 10x Genomics, Inc. Planning Commission <br /> 24 of 32 <br /> Vehicular access to the subject site would be provided from three existing driveways (one on <br /> Stoneridge Mall Road (Phases 2/3), one on Stoneridge Mall Road (ring road) (Phase I), and <br /> one on Springdale Avenue (Phase I and primary)). <br /> PUD-139 and P20-0973, 10x Genomics, Inc. Planning Commission <br /> 19 of 32 <br /><br />