Laserfiche WebLink
Land Use and Zoning <br /> The subject site has a General Plan designation of Medium Density Residential use where <br /> single-family residential use is a compatible use. Consistent with State law and the Pleasanton <br /> Municipal Code (PMC), ADUs are a permitted use within single-family residential districts. <br /> The project site is within the Planned Unit Development (PUD) for the Augustine Knoll <br /> (Greenbriar Homes and KB Homes) residential developments at the Bernal Property, for which <br /> the approved PUD plan establishes site-specific development standards. Applicable <br /> development standards allow for homes to be up to 35 feet in height (as measured from the <br /> foundation elevation to the mid-point of the highest ridge to the eave line), with a maximum <br /> Floor Area Ratio (FAR) of 45%, excluding up to 600 square feet of garage area. <br /> Site Development Standards <br /> Table 1 compares the proposed addition with the applicable site development standards for <br /> the underlying PUD development standards. <br /> Table 1: Approved PUD Development Standards and Proposed Addition <br /> PUD Development Existing Home Proposed Addition <br /> Standard <br /> Setbacks (min. in <br /> feet) <br /> Front yard House — 20' House — 23.62' No change <br /> Garage — 15' Garage —49' <br /> Side yard One side — 10' East side — 12.32' East side — no change <br /> both sides — 20' West side — 15' West side — 15' to building; <br /> 10' to exterior stairway <br /> Rear yard 20' 51' no change <br /> Height (max, in 35' 28'9" 1 24'2" <br /> feet) <br /> FAR (max. in %) 45% 36% 39.79% <br /> 1 For more straightforward illustration and comparison with the project plans, the height used in the report is <br /> measured from the existing grade to the peak of the roof at the proposed addition, rather than as defined by the <br /> PUD (i.e., as measured to the mid-point of the ridge rather than the peak. Based on the latter method, the height <br /> of the proposed addition would be approximately 21'5". <br /> As shown above, the proposed addition would meet all of the development standards of the <br /> underlying PUD. The maximum height of the addition would be approximately 4 feet 7 inches <br /> lower than the existing home (28 feet 9 inches) and is well below the maximum height allowed <br /> by the PUD. The 39.79% FAR is also below the maximum 45% FAR allowed by the PUD. The <br /> addition, built directly above the existing garage, would maintain the existing building setback <br /> which, at 15 feet, exceeds the minimum required. <br /> The existing residence and the westerly property line are not parallel to each other. As such, <br /> the side yard setback increases or widens from the front of house to the rear of the house. The <br /> front of the house is 15 feet to the westerly property line, which increases to 19 feet at the rear <br /> of the house. The mid portion of the house where the proposed exterior stairway would be <br /> located is approximately 17 feet to the westerly property line. <br /> P19-0130 Planning Commission <br /> 9 of 15 <br /> accessory dwelling unit) at the existing two-story residence at 7218 Moss Tree Way. Zoning for <br />e existing two-story residence at 7218 Moss Tree Way. Zoning for <br />