Attachment 1 Exhibit B <br /> 20.24.340 CFC Section 6004.1.6 added—Maximum threshold quantity. <br /> Section 6004.1.6 is added to read: <br /> 6004.1.6 Maximum threshold quantity. Toxic gases stored or used in quantities exceeding the <br /> maximum threshold quantity in a single vessel per control area or outdoor control area or H- <br /> Occupancy shall comply with the additional requirements for highly toxic gases of Section 6004 of <br /> this code. <br /> Moderately toxic gases stored or used in quantities exceeding the maximum threshold quantity in a <br /> single vessel per control area or outdoor control area or H-Occupancy shall comply with the <br /> additional requirements for toxic gases of Section 6004 of this code. <br /> 20.24.350 CFC Section 6004.1.7 added— Reduced flow valve. <br /> Section 6004.1.7 is added to read: <br /> 6004.1.7 Reduced flow valve. All containers of materials other than lecture bottles containing highly <br /> toxic material and having a vapor pressure exceeding 29 psi shall be equipped with a reduced flow <br /> valve when available. If a reduced flow valve is not available,the container shall be used with a flow- <br /> limiting device. All flow limiting devices shall be part of the valve assembly and visible to the eye <br /> when possible; otherwise,they shall be installed as close as possible to the cylinder source. <br /> Exception: When the process use rate is approximately equal to the maximum flow rate of the <br /> cylinder/tank valve. <br /> 20.24.360 CFC Section 6004.1.8 added—Fire extinguishing systems. <br /> Section 6004.1.8 is added to read: <br /> 6004.1.8 Fire extinguishing systems. Buildings and covered exterior areas for storage and use areas <br /> of materials regulated by this Chapter shall be protected by an automatic fire sprinkler system in <br /> accordance with NFPA 13. The design of the sprinkler system for any room or area where highly <br /> toxic,toxic and moderately toxic gases are stored, handled or used shall be in accordance with <br /> Section 5004.5. <br /> 20.24.370 CFC Section 6004.1.9 added— Local gas shut off. <br /> Section 6004.1.9 is added to read: <br /> 6004.1.9 Local gas shut off. Manual activation controls shall be provided at locations near the point <br /> of use and near the source.as approved by the fire code official. The fire code official may require <br /> additional controls at other places, including, but not limited to,the entry to the building, storage or <br /> use areas, and emergency control stations. Manual activated shut-off valves shall be of a fail-safe-to- <br /> close design. <br /> 20.24.380 CFC Section 6004.1.10 added —Exhaust ventilation monitoring. <br /> Section 6004.1.10 is added to read: <br /> Page 35 of 64 <br />