Attachment 1 Exhibit B <br /> Table 6004.1 <br /> Minimum Threshold Quantities for Highly Toxic,Toxic and Moderately Toxic Gases <br /> Highly Toxic 0 cubic feet <br /> Toxic 10 cubic feet <br /> Moderately Toxic 20 cubic feet <br /> 20.24.300 CFC Section 6004.1.2 amended—Gas Cabinets. <br /> Section 6004.1 is hereby amended as follows: <br /> 6004.1.2 Gas cabinets.Gas cabinets containing highly toxic,toxic or moderately toxic gases shall <br /> comply with Section 5003.8.6 and the following requirements: <br /> [balance to remain the same] <br /> 20.24.310 CFC Section 6004.1.3 amended — Exhausted Enclosures. <br /> Section 6004.1.3 is hereby amended as follows: <br /> 6004.1.3 Exhausted enclosures. Exhausted enclosures containing highly toxic, toxic or moderately <br /> toxic gases shall comply with Section 5003.8.5 and the following requirements: <br /> [balance to remain the same] <br /> 20.24.320 CFC Sections 6004.1.4 added—Automatic shut-off valve. <br /> Section 6004.1.4 is added to read: <br /> 6004.1.4 Automatic shut-off valve. An automatic shut-off valve, which is of a fail-safe to close <br /> design, shall be provided to shut off the supply of highly toxic gases as close as possible to the supply <br /> container for any of the following: <br /> 1. Activation of a manual fire alarm system. <br /> 2. Activation of the gas detection system. <br /> 3. Failure of emergency power. <br /> 4. Failure of primary containment. <br /> 5. Seismic activity. <br /> 6. Failure of required ventilation. <br /> 7. Manual activation at an approved remote location. <br /> 20.24.330 CFC Section 6004.1.5 added—Annual Maintenance. <br /> Section 6004.1.5 is added to read: <br /> 6004.1.5 Annual Maintenance. All safety control systems at a facility shall be maintained in good <br /> working condition and tested not less frequently than annually. Maintenance and testing shall be <br /> performed by persons qualified to perform the maintenance and tests. Maintenance records and <br /> certifications shall be kept for a minimum of three years and shall be made available to any <br /> representative of the Livermore-Pleasanton Fire Department for inspection upon request. <br /> Page 34 of 64 <br />
The URL can be used to link to this page
Your browser does not support the video tag.