Attachment 1 Exhibit B <br /> 6004.1.10 Exhaust ventilation monitoring. For highly toxic gases,toxic and moderately toxic gases <br /> exceeding minimum threshold quantities, a continuous monitoring system shall be provided to assure <br /> that the required exhaust ventilation rate is maintained. The system shall monitor actual air flow in the <br /> exhaust system. The monitoring system shall initiate a local alarm. The alarm shall be both visual <br /> and audible and shall be designed to provide warning both inside and outside of the interior storage, <br /> use, or handling area. <br /> 20.24.390 CFC Section 6004.1.11 added—Emergency response plan. <br /> Section 6004.1.11 is added to read: <br /> 6004.1.11 Emergency response plan. If the preparation of an emergency response plan for the <br /> facility is not required by any other law, responsible persons shall prepare, or cause to be prepared, <br /> and filed with the fire code official, a written emergency response plan. If the preparation of an <br /> emergency response plan is required by other law, a responsible person shall file a copy of the plan <br /> with the fire code official. <br /> 20.24.400 CFC Section 6004.1.12 added—Emergency Response Liaisons. <br /> Section 6004.1.12 is added to read: <br /> 6004.1.12 Emergency Response Liaisons. Responsible persons shall be designated and trained to be <br /> liaison personnel for the Livermore-Pleasanton Fire Department. There persons shall aid the Fire <br /> Department in preplanning emergency responses and understanding the materials and operations <br /> utilizing the gases. <br /> 20.24.410 CFC Section 6004.1.13 added— Emergency Drills. <br /> Section 6004.1.13 is added to read: <br /> 6004.1.13 Emergency Drills. Emergency drills of the on-site emergency response personnel and <br /> liaisons shall be conducted on a regular basis but not less than every six months. Records of drills <br /> conducted shall be maintained for three years. <br /> 20.24.420 CFC Section 6004.1.14 added—Cylinder leak testing. <br /> Section 6004.1.14 is added to read: <br /> 6004.1.14 Cylinder leak testing.Cylinders shall be tested for leaks immediately upon delivery and <br /> again immediately prior to departure. Testing shall be approved by the fire code official in accordance <br /> with appropriate nationally recognized industry standards and practices, if any. Appropriate remedial <br /> action shall be immediately undertaken when leaks are detected. <br /> 20.24.430 CFC Section 6004.1.15 added—Inert gas purge system. <br /> Section 6004.1.15 is added to read: <br /> 6004.1.15 Inert gas purge system.Gas systems shall be provided with dedicated inert gas purge <br /> systems. A dedicated inert gas purge system may be used to purge more than one gas, provided the <br /> gases are compatible. Purge gas systems inside buildings shall be located in an approved gas cabinet <br /> unless the system operates by vacuum demand. <br /> Page 36 of 64 <br />
The URL can be used to link to this page
Your browser does not support the video tag.