Laserfiche WebLink
4 <br /> <br />approved lab for testing of the sand and gravel to ensure both materials meet the minimum “bridging” standard. <br />This common standard is based on engineering principles that rely on the largest 15% of the sand particles <br />"bridging" with the smallest 15% of the gravel particles. The gravel must be placed evenly and raked smooth. <br /> <br />Prior to placement of the gravel blanket Contractor will provide OWNER or AGENT with a record drawing <br />(As-built) of the installed drainage showing the percentages of fall. In addition to the record drawing Contractor <br />will provide to OWNER or AGENT digital photos, on USB flash drive, showing the complete drainage system. <br /> <br />8.3. ST410 Polymer Binder Application <br />ST410 POLYMER shall be sprayed by a certified and trained Better Billy Bunker or other approved <br />manufacturer installer. Using proper pressure spray equipment, a uniform layer of ST410 POLYMER shall be <br />applied to the gravel in the bunker at a rate of one (1) gallon of ST410 POLYMER per 30-35 square feet. The <br />gravel must be dry (less than 15% as tested by the certified installer) at application time. The treated bunker <br />shall be allowed to cure for approximately 24 hours prior to sand installation. NOTE: ST410 POLYMER will <br />penetrate approximately ½ - 1 inch (12mm - 25mm) depth of the gravel. A sturdy pliable layer of glued gravel <br />will be the result. <br /> <br />8.4. Inspection and Quality Control <br />After 12-24 hours, the initial ST410 POLYMER application will have cured. Contractor will walk and inspect <br />every square foot (meter) of each bunker at the end of the curing process. Any areas not to have received the <br />specified rate of polymer will be marked with turf paint and re-sprayed prior to calling for a final inspection by <br />OWNER or AGENT. Improper application or omitting of the inspection process and follow up polymer <br />application could result in weak areas and/or loose gravel. It is the installer’s responsibility to inspect and <br />maintain the highest standards when installing the Better Billy Bunker or approved equal. <br /> <br />9. SUBSURFACE IRRIGATION SYSTEM INSTALLATION <br />In conjunction with the soil preparation needed for the sod installation, a subsurface irrigation <br />system is to be installed around the perimeter of each renovated bunker. <br /> <br />9.1. Subsurface Irrigation Parts <br />Subsurface drip line shall be Toro DL2000 (low flow) and Drip Zone Valve Kit <br />which includes control valve, pressure regulator, Y-filter and manual ball valve. <br />Toro air vent assembly, flush assembly fittings and all associated fittings to be <br />supplied by Contractor. Drip line spacing to be 12 inches or as directed by the <br />Golf Course Superintendent. <br /> <br />10. RE-SODDING OF DISTURBED AREAS <br />All sand bunker banks and slopes leading away from edges that have been damaged during the bunker work shall <br />be sodded as directed by OWNER or AGENT. If slopes are greater than 3:1, Contractor shall use wooden stakes <br />to hold the sod in place until established. Wooden stakes must be of sufficient length to provide firm bearing. <br /> <br />10.1. Surface Preparation <br />All surfaces within the areas of disturbance to be re-sodded, which are slicked or glazed shall be scarified, <br />amended, and smoothed by floating or hand raking prior to planting. All areas to be sodded shall be floated in <br />two directions to eliminate water holding depressions and pockets. All lumps and soil clods shall be eliminated. <br />Soil amendments and fertilizers to be supplied by the City. <br /> <br />10.2. Sod Quality <br />Sod will be cut in a uniform thickness width and length. Sod shall be delivered to the job site within twenty- <br />four hours after being harvested. Any sod permitted to dry out or rot may be rejected if, in the judgment of <br />OWNER or AGENT, its survival after placement is doubtful, and shall be replaced at the sole cost of the <br />Contractor. <br />Docusign Envelope ID: 06528EA8-C8FB-4176-8C2E-D53F24B897F0