Laserfiche WebLink
4. Specifications and Standard Details - The City Engineer is authorized <br />to modify the City's existing Standard Specifications and Details in <br />applying them to this subdivision in order to allow for modern mater- <br />ials, methods and design criteria as may be required. Some specific <br />modifications are as follows: <br />a. Specifications for sewer and water pipe shall be modified to <br />allow newer type joints. <br />b. Specifications for street name signs shall be modified to require <br />white reflectorized letters, block numbers and arrows on green <br />coated aluminum sheeting as previously approved by the Planning <br />Commission and City Council. <br />c. Street structural design method shall be modified to require <br />design by the California R -Value method using a Traffic Index <br />for each street as specified by the City Engineer. <br />d. Reference shall be made to the 1960 Standard Specifications of <br />the State Division of Highways, rather than the 1954 edition, <br />particularly with reference to roadway materials. <br />5. Storm Drainage System - The culverts under the Mirador Drive ex- <br />tension and the Hillview Ave. - Kottinger Ave. intersection shall be <br />increased to 72" and 66" respectively. The street cross section for <br />hillside streets shall be changed to require a roadside drainage <br />ditch on the uphill side, and all paved gutters shall be connected <br />to pipe outside of the street right -of -way. <br />6. Water Supply and Distribution System <br />Minor changes in pipe sizes shall be made as shown on the approved <br />Tentative Map. The system as shown (modified) is approved for serv- <br />ing the development. If subsequent master planning indicates the <br />desirability of relocating or oversizing the storage tank or any <br />distribution mains in order to serve other areas and effectuate a <br />Master Water Plan, the developer shall cooperate with the City in <br />providing such changes after negotiating with the City any cost dif- <br />ferential. <br />74 Sewage Collection System. All curved sewer lines shall have a <br />minimum radius of 200 feet. <br />8. Fire Hvdrapts is Fire hydrants shall be located as shown on the ap- <br />proved Tentative Map, <br />9. Electric Power Distribution and Street Lighting Systems • A "modified" <br />underground system (P.G.& E. "Streamlined Distribution" system) shall <br />be used on the first unit of development proposed, approximately 40 <br />acres along Kottinger Ave. with the easterly limit being Hillview <br />Ave. Based on information developed from this first installation <br />a re- evaluation will be made, and the City will determine the method <br />of installation to be used for the remaining portion of this tenta- <br />tive map. <br />- 2 - <br />