JOSEPH BOATRIGHT AND RAYMOND GOODRICH
NOTES 2
HILLSIDE DEVEL. PLAN FOR 28 UNITS
NOTES 3
INTERSECTION OF BERNAL AVE/FOOTHILL RD.
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Res. 1808 <br />~._ Pg. 3 <br />13. That the staff request that the public report of the <br />California Real Estate Commissioner contain a warning <br />as to the current unavailability of sewer connections. <br />14. That the developer be advised that the property is <br />located in the Dublin-San Ramon Services District <br />sewage treatment area and the availability of sewer <br />connections to the DSRSD plant is subject to an <br />agreement dated November 8, 1972 which establishes <br />priority listings for sewer connections. A copy of <br />the above agreement can be obtained from the City <br />Administrative offices. That the developer be <br />informed that sufficient sewer connections are not <br />now available to serve the subject property, that the <br />time schedule when service would become available <br />is uncertain (if ever), and that a building permit <br />cannot be issued for construction on the property <br />until sewage treatment capacity is available. <br />15. That there shall be no septic tanks on the site <br />under any conditions. <br />16. That a fire retardant buffer 10 ft. in width shall <br />~- be provided along the length of both sides of the <br />private roadway and be engineered and landscaped in <br />such a way as to minimize erosion to a level acceptable <br />to the City Engineer. <br />17. That street lighting and common area lighting shall <br />be provided by the developer and shall be designed to <br />minimize intrusion of hillside lighting to the valley <br />floor as concurred with by the City Planning Division. <br />The lighting system on the private road shall be <br />installed by the developer and maintained by the <br />homeowner's association. <br />18. That the deed restrictions for each lot indicate to <br />potential buyers the responsibility of the owners <br />for maintenance and repair of all common areas, roadways <br />and private utility and service systems. <br />19. That the fire hydrant and water system be designed to <br />provide a water flow of 1500 gpm. <br />20. That the fire hydrants and other fire department con- <br />nections shall be located and sized as directed by the <br />City Fire Chief. <br />21. That the location of all buildings shall be such that <br />the farthest exterior wall of a structure shall be <br />within 150 ft. of an appropriately designed access road <br />