more than 6 inches on center along all panel edges and 12 inches on center along <br />intermediate framing members. Wall openings for doors or windows are permitted <br />provided a minimum 4 foot wide wood structural braced panel with minimum height to <br />length ratio of 2 to 1 is provided at each end of the wall line and that the wall line be <br />sheathed for 50% of its length. <br />(Balance of section to remain). <br />20.08.042 -This Section is Deleted. <br />20.08.043 Section 903.2 amended -Where Required. <br />Section 903.2 Where Required of the California Building Standards Code 2007 Edition <br />(24 C.C.R.), and including by reference the International Building Code, 2006 Edition, <br />Volumes 1 and 2, is amended to read as follows: <br />903.2 An automatic fire extinguishing system or other approved fire suppression <br />system(s) shall be installed as follows: <br />1. In every building where the floor and basement area exceeds 8000 square feet. <br />Exceptions: <br />1. Group U, Division 1 private garages of 1,000 square feet or less. <br />2. Group U, Division 2 Occupancies. <br />2. In all buildings of all occupancies except Groups R1, R3 and U occupancies on a <br />parcel when the building(s) area(s) on the parcel exceeds 8,000 square feet of floor <br />area, including area of basements. <br />3. All buildings residential or commercial over 5 minutes response time, as determined <br />by the Fire chief, from a City fire station. <br />4. Any structure in any area or location determined by the Fire Chief to be a high fire <br />hazard. High fire hazard area shall be defined as those areas beyond five minutes <br />driving time of fire apparatus from the fire station searing those particular districts; or <br />areas determined by the Fire Chief to be either high hazard areas or extreme hazard <br />areas based on steepness of slope and/or fuel loadings from combustible plant <br />materials as set forth in the Safety Element of the General Plan. <br />5. In every story or basement of all buildings when the floor area exceeds 1,500 <br />square feet (139.4 m2) and there is not provided at least 20 square feet (1.86 m2) of <br />opening entirely above the adjoining ground level in each 50 lineal feet (15 240 mm) or <br />fraction thereof of exterior wall in the story or basement on at least one side of the <br />building. Openings shall have a minimum dimension of not less than 30 inches (762 <br />mm). Such openings shall be accessible to the fire department from the exterior and <br />shall not be obstructed in a manner that firefighting or rescue cannot be accomplished <br />from the exterior. When openings in a story are provided on only one side and the <br />opposite wall of such story is more than 75 feet (22 860 mm) from such openings, the <br />42 <br />