My WebLink
|
Help
|
About
|
Sign Out
ORD 1965
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1901 - 2000
>
ORD 1965
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:23:47 PM
Creation date
1/9/2008 11:34:53 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 1965
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
story shall be provided with an approved automatic sprinkler system, or openings as <br />specified above shall be provided on at least two sides of an exterior wall of the story. <br />If any portion of a basement is located more than 75 feet (22 860 mm) from openings <br />required in this section, the basement shall be provided with an approved automatic <br />sprinkler system. <br />6. At the top of rubbish and linen chutes and in their terminal rooms. Chutes extending <br />through three or more floors shall have additional sprinkler heads installed within such <br />chutes at alternate floors. Sprinkler heads shall be accessible for servicing. <br />7. In rooms where nitrate film is stored or handled. <br />8. In protected combustible fiber storage vaults as defined in the Fire Code. <br />9. Throughout all buildings with a floor level with an occupant load of 30 or more that is <br />located 55 feet (16 764' mm) or more above the lowest level of fire department vehicle <br />access. <br />EXCEPTION: 1. Airport control towers. <br />(Balance of section to remain). <br />20.08.044 -This Section is Deleted. <br />20.08.045 Section 903.2.7 amended- Group R. <br />Section 903.2.7 Group R of the California Building Standards Code 2007 Edition (24 <br />C.C.R.), and including by reference the International Building Code, 2006 Edition, <br />Volumes 1 and 2, is amended to read as follows: <br />903.2.7 Installation of Fire Sprinklers in Residential Occupancies. The installation of <br />fire sprinkler systems in Grope R buildings up to fifteen (15) units and up to a maximum <br />of twelve thousand (12,000) square feet maximum shall be accomplished using the <br />National Fire Protection Association (NFPA) 13D-2005 Edition as may be herewith <br />amended. <br />Chapter 1-General Information. <br />Section 1-1 Scope: <br />This standard describes the requirements for the mechanical and performance <br />properties of the sprinkler itself. It also describes the requirements for the installation of <br />the complete sprinkler system for residential occupancies up to fifteen (15) units or <br />twelve thousand square feet (12,000) maximum. <br />Chapter 1-General Information -amended <br />Section 1-5.4 is amended to read: <br />43 <br />
The URL can be used to link to this page
Your browser does not support the video tag.