My WebLink
|
Help
|
About
|
Sign Out
ORD 1965
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1901 - 2000
>
ORD 1965
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:23:47 PM
Creation date
1/9/2008 11:34:53 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 1965
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 2308.12.4 <br />WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E <br />(Minimum Length of Wall Bracing per each 25 Linear Feet of Braced Wall Line°) <br />CONDITION SHEATHING Sos < 0.50 0.50 < Sos < 0.75< Sos < S ~ > 1.00 <br /> TYPE 0.75 1.00 <br />One Story S-W 5 feet 4 inches 8 feet 0 inches 9 feet 4 inches 12 feet 0 <br /> inches <br />Story Below Top S-W 10 feet 8 inches 13 feet 4 inches 17 feet 4 inches 21 feet 4 inches <br />Story (HCD 1) <br />Bottom story of <br />three stories S-W COI Conventional construction not permitted <br />(HCD -1) <br />For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. <br />a. Minimum length of panel bracing of one face of the wall for S-W sheathing shall be at least 4'-0" long, h/w ratio shall not exceed 2:1. For <br />S-W panel bracing of the same material on two faces of the wall, the minimum length is permitted to be one-half the tabulated value but the h/w <br />ratio shall not exceed 2:1 and design for uplift is required. <br />b. (HCD 1) Applies to detached one-and two- family dwellings only. <br />S-W =Wood structural panels shall be nailed with 15/32" thick 8d nails, at 6:6:12. <br />20.08.040 -Section 2308.12.4 -Braced wall line sheathing. <br />Section 2308.12.4 Braced wall line sheathing of the California Building Standards Code <br />2007 Edition (24 C.C.R.), and including by reference the International Building Code, <br />2006 Edition Volumes 1 and 2 is amended to read as follows: <br />2308.12.4 Braced wall line sheathing. Braced wall lines shall be braced by one of the <br />types of sheathing prescribed by Table 2308.12.4 as shown in Figure 2308.9.3. The <br />sum of lengths of braced wall panels at each braced wall line shall conform to Table <br />2308.12.4. Braced wall panels shall be distributed along the length of the braced wall <br />line and start at not more than 8 feet (2438mm) from each end of the braced wall line. <br />Panel sheathing joints shall occur over studs or blocking. Sheathing shall be fastened <br />to studs, top and bottom plates and at panel edges occurring over blocking. Wall <br />framing to which sheathing used for bracing is applied shall be nominal 2 inch wide [1 1/i <br />inch (38 mm)] or large members. <br />Braced wall panel construction types shall not be mixed within a braced wall line. <br />Braced wall panels required by Section 2308.12.4 may be eliminated when all of the <br />following <br />requirements are met: <br />1. One story detached garage Group U occupancies not more than 25 feet in depth or <br />length. <br />2. The roof and three enclosing walls are solid sheathed with 1h-inch nominal thickness <br />wood <br />structural panels with Sd common nails placed 3/8 inches from panel edges and spaced <br />not <br />41 <br />
The URL can be used to link to this page
Your browser does not support the video tag.