Staples for the attachment of gypsum lath and woven-wire lath shell have a minlmum crown width of/, Inch, measured outside the legs. <br />20.08.038 Section 2308.12.5 amended -Attachment of sheathing. <br />Sections 2308.12.5 Attachment of sheathing of the California Building Standards Code <br />2007 Edition, (24 C.C.R.), and including by reference the International Building Code, <br />2006 Edition, Volumes 1 and 2 is amended to read as follows: <br />2308.12.5 Attachment of sheathing. Fastening of braced wall panel sheathing shall not <br />be <br />less than that prescribed in Table 2308.12.4 or Table 2304.9.1. Wall sheathing shall not <br />be attached to framing members by adhesives. <br />All braced wall panels shall extend to the roof sheathing and shall be attached to <br />parallel roof rafters or blocking above with framing clips (18 gauge minimum) spaced at <br />maximum 24 inches (6096 mm) on center with four 8d nails per leg (total eight 8d nails <br />per clip). Braced wall panels shall be laterally braced at each top corner and at <br />maximum 24 inch (6096 mm) intervals along the top plate of discontinuous vertical <br />framing. <br />20.08.039 Table 2308.12.4 amended -Wall Bracing in Seismic Design Categories D <br />and E. <br />Table 2308.12. Wall Bracing in Seismic Design Categories D and E of the California <br />Building Standards Code 2007 Edition, (24 C.C.R.), and including by reference the <br />International Building Code, 2006 Edition, Volumes 1 and 2 is amended to read as <br />follows: <br />40 <br />