My WebLink
|
Help
|
About
|
Sign Out
1488
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1970-1979
>
1977
>
1488
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2008 12:22:40 PM
Creation date
12/7/2007 3:50:44 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
2/9/1977
DOCUMENT NO
PC 1977-1488
DOCUMENT NAME
PUD-76-3
NOTES
MORRISON HOMES
NOTES 2
PLANNED UNIT DEVELOPMENT
NOTES 3
S DEL VALLE PARKWAY, E HOPYARD RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
15. That the number, size and location of fire hydrants <br />remain subject to change pending approval by the <br />Fire Division. <br />16. That the developer provide all the street lighting <br />facilities necessary to adequately light the streets <br />within and adjacent to this tract at the lowest <br />possible cost to the City. <br />17. That electric power distribution and communication <br />service system be placed totally underground ex- <br />cept for above-ground splicing cabinets where <br />necessary. <br />18. That approval of the water supply and distribution <br />system be withheld until the developer has demon- <br />strated to the satisfaction of the City Engineer <br />that the proposed system meets the requirements <br />for supplying water for this area. <br />19. That approval of the sanitary sewer system be <br />withheld until the developer has demonstrated to <br />the satisfaction of the City Engineer that the <br />proposed system meets requirements of the sanitary <br />sewer system. <br />20. That approval of the storm drainage system be with- <br />held until final design calculations have been made <br />and the developer has demonstrated to the satis- <br />faction of the City Engineer that the system fully <br />meets the requirements of this development and all <br />upstream areas intended to be drained through this <br />tract and that the requirements of Alameda County <br />Flood Control District have been met. <br />21. That approval of the precise design of streets and <br />street improvements be withheld pending final <br />design, review and approval. <br />22. That all wells and septic tanks on the property be <br />properly sealed, filled, and abandoned prior to the <br />start of grading operations on the tract development. <br />23. That a grading plan be submitted for approval as a <br />part of the improvement plans and that the minimum <br />grade for streets or drives be set at .5~ unless <br />otherwise approved by the City Engineer. <br />24. That the developer be reminded that specific approval <br />from City Council will be required prior to removal <br />of any Heritage Trees and that preservation measures <br />on the trees to be preserved will be required during <br />tract and house development. <br />-3- <br />
The URL can be used to link to this page