applications listed in Section 111 regulated <br />Marshal, exterior walls shall be fire-resistanc <br />601 and 602. The fire-resistance rating of <br />exposure to fire from both sides. <br />20.08.059 -This Section is Deleted. <br />by the Office of the State Fire <br />e rated in accordance with Tables <br />exterior walls shall be rated for <br />20.08.060 Table 704.8 amended -Maximum Area of Exterior Wall Openings. <br />Table 704.8 Maximum Area of Exterior Wall Openings of the California Building <br />Standards Code 2007 Edition, (24 C.C.R.), and including by reference the International <br />Building Code, 2006 Edition, Volumes 1 and 2 is amended to read as follows: <br />TABLE 704.8 <br />MAXIMUM AREA OF EXTERIOR WALL OPENINGS <br />CLASSIFICATION FIRE SEPARATION DISTANCE (feet) <br /> <br />OF OPENING <br /> 0 to 3f~ Greater Greater Greater Greater Greater Greater Greater <br /> than 3 to <br />Se•g than 5 to <br />I Oe.e.6.h than 10 <br />to I S`1e,g than 15 <br />to 20d•g than 20 <br />to 25`~•g than 25 <br />to 3Oa'g than 30 <br />Unprotected Not <br /> <br />Permitted Not <br /> <br />Permitted Not <br /> <br />Permitted° 15% <br />25%' 45%; 70% No Limit <br />Protected Not <br /> <br />Permitted <br />15% 25% 45% 75% <br />No Litnit <br />No Limit <br />No Limit <br />For SI: 1 foot = 304.8 mm. <br />a. Values given are percentage of the area of the exterior wall. <br />b. Not used <br />c. For occupancies in Group R-3, the maximum percentage of unprotected and protected exterior wall openings shall be 25 percent. <br />d. The area of openings in an open parking structure with a fire separation distance of greater than 10 feet shall not be limited. <br />e. For occupancies in Group H-2 or H-3, unprotected openings shall not be permitted for openings with a fire separation distance of <br />I S feet or less. <br />f. For requirements for fire walls for buildings with differing roof heights, see Section 705.6.1. <br />g. The area of unprotected and protected openings is not litnited for occupancies in Group R-3, with a fire separation distance greater <br />than 5 feet. <br />h. For special requirements for Group U occupancies, see Section 406.1.2. <br />i. Includes accessory buildings to Group R-3. <br />20.08.061 Section 704.3 amended -Buildings on the same lot. <br />Section 704.3 Buildings on the same lot of the California Building Standards <br />Code 2007 Edition, (24 C.C.R.), and including by reference the International <br />Building Code, 2006 Edition, Volumes 1 and 2 is amended to read as follows: <br />52 <br />