704.3 Buildings on the same lot. For the purposes of determining the required <br />wall and opening protection and roof-covering requirements, buildings on the <br />same lot shall be assumed to have an imaginary property line between them. <br />Where a new building is to be erected on the same lot as an existing building, <br />the location of the assumed imaginary property line with relation to the existing <br />building shall be such that the exterior wall and opening protection of the existing <br />building meet the criteria as set forth in Sections 704.5 and 704.8. <br />Exception: Two or more buildings on the same lot shall either be regulated as <br />separate buildings or shall be considered as portions of one building if the <br />aggregate area of such buildings is within the limits specified in Chapter 5 for a <br />single building. Where the buildings contain different occupancy groups or are of <br />different types of construction, the area shall be that allowed for the most <br />restrictive Occupancy or construction. <br />20.08.061 -This Section is Deleted. <br />20.08.062 -This Section is Deleted. <br />20.08.063 Section 704.8.1 amended -Automatic sprinkler system. <br />Section 704.4.8.1 Automatic Sprinkler System of the California Building Standards <br />Code 2007 Edition, (24 C.C.R.), and including by reference the International Building <br />Code, 2006 Edition, Volumes 1 and 2 is amended to read as follows: <br />704.8.1 Automatic sprinkler system. In buildings with a property line or fire separation <br />distance greater than 10 feet (3048 mm) and equipped throughout with an automatic <br />sprinkler system in accordance with Section 903.3.1.1, the maximum allowable area of <br />unprotected openings in occupancies other than Groups H-1, H-2 and H-3 shall be the <br />same as the tabulated limitations for protected openings. <br />20.08.064 -This Section is Deleted. <br />20.08.065 Section 907.2.10.1.2 amended -Groups R-2, R-3, R3.1, R-4 and I-1. <br />Section 907.2.10.1.2 Groups R-2, R-3, R3.1, R-4 and I-1 of the California <br />Building Standards Code 2007 Edition, (24 C.C.R.), and including by reference <br />the International Building Code, 2006 Edition, Volumes 1 and 2 is amended to <br />read as follows: <br />907.2.10.1.2 Groups R-2, R-3, R-3.1, R-4 and I-1. Single- or multiple-station <br />smoke alarms shall be installed and maintained in Groups R-2, R-3, R-3. 1, R-4 <br />and I-1, regardless of occupant load at all of the following locations: <br />53 <br />
The URL can be used to link to this page
Your browser does not support the video tag.