Section 3-3 Piping is amended: <br />Section 3-3 is amended to delete all references to ferrous metal pipe. Ferrous metal <br />pipe is not permitted. <br />Section 3-6 Alarms is amended to read: <br />Local water flow alarms shall be provided on all sprinkler systems. Water flow alarms <br />and valve tamper shall be connected to an Underwriters Laboratory (UL) listed Central <br />Station Service under the following conditions: <br />(a) All buildings with eight (8) or more units or, <br />(b) When there are four (4) or more buildings per complex or, <br />(c) When there are more than sixty-four (64) units per complex. <br />CHAPTER 4-System Design -amended <br />Section 4-1.2.1. Number of Design Sprinklers and Water Demand is amended to read: <br />The number of design sprinklers shall be as follows: <br />(a) Standard for One (1) to Four (4) Dwelling Units up to twelve thousand (12,000) <br />square feet. <br />The number of design sprinklers shall include all sprinklers within a compartment <br />to a maximum of four (4) sprinklers. When the number of design sprinklers is less than <br />four (4) for a compartment, the design shall include a five (5) gallon per minute <br />domestic use simultaneous with sprinkler flow per unit. This domestic use shall be <br />calculated at the base of riser. <br />Pilot sprinklers shall be provided in the attic and between floors where floor/ceiling <br />assemblies consist of open web wood joists or trusses. Pilot sprinklers shall be 212 <br />degree F, 7/1 g inch orifice. Pilot sprinklers shall be located at maximum 30 feet centers <br />(Maximum 15 feet from outside walls) and shall be located at all heat and fire sources <br />including furnaces, hot water heaters, above kitchen ranges, etc. Fire sprinklers in <br />garages shall be 200 degree F, quick response, 7/16 inch orifice (K=4.0 to 4.5) with a <br />maximum spacing of 130 to 150 square feet per sprinkler. <br />(b) Standard for Mid-Sized Multi-Family Residential <br />Fifteen (15) Dwelling Units in Residential Structure <br />square feet (12,000 square feet) shall be as follows: <br />Sprinkler Systems for Five (5) to <br />s Not Exceeding twelve thousand <br />44 <br />
The URL can be used to link to this page
Your browser does not support the video tag.