My WebLink
|
Help
|
About
|
Sign Out
14
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2007
>
120407
>
14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2007 2:27:21 PM
Creation date
11/28/2007 12:27:52 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
15 Y
DOCUMENT NO
14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 903.2.7 Group R of the California Building Standards Code 2007 Edition (24 <br />C.C.R.), and including by reference the International Building Code, 2006 Edition, <br />Volumes 1 and 2, is amended to read as follows: <br />903.2.7 Installation of Fire Sprinklers in Residential Occupancies. The installation of <br />fire sprinkler systems in Grope R buildings up to fifteen (15) units and up to a maximum <br />of twelve thousand (12,000) square feet maximum shall be accomplished using the <br />National Fire Protection Association (NFPA) 13D-2005 Edition as may be herewith <br />amended. <br />Chapter 1-General Information. <br />Section 1-1 Scope: <br />This standard describes the requirements for the mechanical and performance <br />properties of the sprinkler itself. It also describes the requirements for the installation of <br />the complete sprinkler system for residential occupancies up to fifteen (15) units or <br />twelve thousand square feet (12,000) maximum. <br />Chapter 1-General Information -amended <br />Section 1-5.4 is amended to read: <br />Section 1-5.4 All systems shall be tested for leakage at 200 psi for one (1) hours <br />mininum. <br />Chapter 1-General Information -added <br />Section 1-5.6 is added to read: <br />Section 1-5.6 All sprinkler piping shall be either non-ferrous metallic pipe (copper, or <br />brass) or CPVC. All piping above the flow switch should be protected by sheet rock or <br />plywood. Note: No ferrous (black iron, iron or galvanized) pipe is permitted. Fire <br />sprinkler riser check valves shall be approved by the City and Fire Prevention Bureau. <br />CHAPTER 3-System Components -amended <br />Section 3-1.1 Valves and Drains is amended: <br />Section 3-1.1 Exception No. 1 (a) amended to read: <br />(a) To a Underwriters Laboratory (UL) listed Central Station Service. <br />(b) Delete (b) and (c). <br />CHAPTER 3--System Components -amended: <br />43 <br />
The URL can be used to link to this page
Your browser does not support the video tag.