Laserfiche WebLink
28. That approval of the storm drainage system be withheld pending <br /> final design and until the developer has demonstrated to the <br /> satisfaction of the City Engineer that the system is adequate, <br /> connects to an approved point of discharge, meets any and all <br /> applicable requirements of the Alameda County Flood Control <br /> District - Zone 7, meets any and all applicable requirements of <br /> the Federal Emergency Management Flood Hazard Program, and meets <br /> the immediate and long-range requirements of this development and <br /> all upstream areas intended to be drained through this <br /> development. <br /> <br />29. That electric power distribution, gas distribution, communication <br /> service, and any required alarm systems be installed underground <br /> in a joint utility trench unless otherwise specifically approved <br /> by the City Engineer. <br /> <br />30. That the developer be responsible for the installation of the <br /> street lighting system serving the development. The street <br /> lights shall be 70 watt, high pressure sodium vapor units mounted <br /> on galvanized steel poles with poured in place bases,on the LS-lC <br /> schedule per City requirements and P.G.& E. standard details <br /> unless otherwise specifically approved. Approval for the number, <br /> location, and type of electroliers shall be withheld pending <br /> final design and review by the City Engineer. <br /> <br />31. That this development provide a safe and effective circulation <br /> system for bicycles and pedestrians. These facilities shall be <br /> designed and installed to the satisfaction of the City Engineer <br /> and shall be separated from vehicular traffic whenever possible. <br /> <br />32. That the developer submit detailed landscape and irrigation plans <br /> as part of the improvement plans. These plans should include, <br /> where applicable, a street tree planting plan and landscape plans <br /> for medians, buffer strips, and any right-of-way landscape areas. <br /> The irrigation plan shall provide automatic controls. <br /> <br />33. That any damage to street improvements now existing or done <br /> during construction on the subject property be repaired to the <br /> satisfaction of the City Engineer at full expense to the <br /> developer. This shall include slurry seal, overlay, or street <br /> reconstruction if deemed warranted by the City Engineer. <br /> <br />34. The location and alignment of Crestablanca Drive at Montevino <br /> Drive shall be revised to the satisfaction of the City Engineer <br /> to provide a more nearly perpendicular intersection. <br /> <br />35. The right-of-way width of "Beratlis Court" and "Finovino Court" <br /> shall be revised from 42' to 46'. <br /> <br /> <br />