Laserfiche WebLink
20.08.034 <br />methods: <br />4.1 Wood boards of 5/8 inch (16 <br />mm) net minimum thickness applied <br />diagonally on studs spaced not over <br />24 inches (610 mm) on center. <br />4.2 Wood structural panel sheathing <br />with a thickness not less than 5/16 <br />inch (7.9 mm) for 16 inch (406 mm) <br />stud spacing and not less than 3/8 <br />inch (9.5 mm) for 24 inch (610 mm) <br />stud spacing in accordance with Ta- <br />bles 23-II-A-1 and 23-IV-D-1. <br />4.3 Fiberboard sheathing 4 foot by <br />8 foot (1219 mm by 2438 mm) <br />panels not less than 1/2 inch (13 <br />mm) thick applied vertically on <br />studs spaced not over 16 inches <br />(406 mm) on center when installed <br />in accordance with Section 2315.6 <br />and Table 23-II-J. <br />4.4 Particleboard wall sheathing <br />panels where installed in accordance <br />with Table 23-IV-D-2. <br />(Ord. 1869 § 2, 2002; Ord. 1778 § 2, <br />1999) <br />20.08.038 Section 1629.4.2 <br />Amended -Seismic Zone 4 <br />Near-Source Factor: <br />Section 1629.4.2 of the California <br />Building Standards Code 2001 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code, is amended <br />to read as follows: <br />1629.4.2. Seismic Zone 4 near- <br />source factor. In Seismic Zone 4, <br />each site shall be assigned anear- <br />source factor in accordance with <br />Table 16-S and the Seismic Source <br />Type set forth in Table 16-U. The <br />value of Na used in determining CQ <br />need not exceed 1.1 for structures <br />complying with all the following <br />conditions: <br />1. The soil profile type is SA, Se, S~ <br />or So. <br />2. p = 1.0. <br />3. Except in single-story structures, <br />Group R, Division 3 and Group U, <br />Division 1 Occupancies, moment <br />frame systems designated as part of <br />the lateral-force-resisting system <br />shall be special moment-resisting <br />frames. <br />4. The provisions in Sections 9.6a <br />and 9.6b of AISC -Seismic Part 1 <br />shall not apply, except for columns <br />in one-story buildings or columns at <br />the top story of multistory buildings. <br />5. None of the following structural <br />irregularities is present: Type 1, 4 or <br />5 of Table 16-L, and Type 1 or 4 of <br />Table 16-M. <br />(Ord. 1869 § 2, 2002; Ord. 1778 § 2, <br />1999) <br />20.08.039 Section 1630.8.2.2 - <br />Amended -Detailing <br />Requirements In Seismic <br />Zones 3 And 4: <br />Section 1630.8.2.2 of the California <br />Building Standards Code 2001 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code, is amended <br />to read as follows: <br />1630.8.2.2 Detailing requirements <br />in Seismic Zones 3 and 4. In Seis- <br />mic Zones 3 and 4, elements support- <br />ing discontinuous systems shall meet <br />700-5 (Pleasanton April 2003) <br />