My WebLink
|
Help
|
About
|
Sign Out
15
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2007
>
032007
>
REGULAR MEETING
>
15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2007 1:12:06 PM
Creation date
3/15/2007 12:47:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
3/20/2007
DESTRUCT DATE
15 Y
DOCUMENT NO
15
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vineyard Ave Water Booster Pump Station and Zone 7 Turnout # 6 <br />Construction Phase Engineering Proposal <br />March 9, 2007 <br />Page 10 of 18 <br />sal~~r Erlglo~2rhg <br />F. Distribution of the submittals: Who, number of submittals, date sent <br />and dates returned, and status. Status states if the submittal is under <br />review, returned as no exceptions taken, make corrections noted, <br />amend and resubmit or rejected. <br />G. Status of compiled response. <br />H. E-mail copies of the submittal log in Microsoft Excel Version 2003 <br />format to CONTRACTOR, the City of Pleasanton and others on a <br />weekly basis <br />3. Perform cursory review of shop drawing submittals to ensure that they <br />comply with the overall format requirements of SECTION 01340 of the <br />CONTRACT SPECIFICATIONS and that a sufficient quantity of submittal <br />copies has been supplied. Shop drawing submittals failing in either respect <br />may, at Garber Engineering's option: <br />A. Returned to the CONTRACTOR with a short explanation of why <br />the submittal was returned without comment. <br />B. Contact the CONTRACTOR to request changes or additional <br />information to bring the submittal into compliance with the format <br />requirements and quantity of submittals. <br />In any case, the CONTRACTOR shall be informed that he is responsible for <br />the delays and the 15 working day response time does not begin until the <br />submittal meets the requirements for format and quantity of submittals. <br />4. Distribute the shop drawing submittals to the various parties expected to <br />review the submittal. This may include: <br />A. The City of Pleasanton. <br />B. Subconsultants to Garber Engineering. <br />5. Review shop drawing submittals for compliance with design and intent of <br />CONTRACT DOCUMENTS. Garber Engineering's review will be for <br />general compliance with the intent of the design. <br />6. Contact parties to whom shop drawing submittals have been distributed to <br />attempt to expedite responses. <br />7. Receive comments from parties to whom shop drawing submittals have <br />been distributed. <br />8. Examine all comments generated by Garber Engineering and those <br />generated by other parties to determine if all the comments are consent. <br />C\DOCUenems and SrttingsNdmNew Gorber\Mc Uocumems\PROI\COPUa2\COPna2 Paul npd <br />
The URL can be used to link to this page
Your browser does not support the video tag.