My WebLink
|
Help
|
About
|
Sign Out
PC 2006-03
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2000-2009
>
2006
>
PC 2006-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2007 4:47:45 PM
Creation date
8/28/2006 8:43:44 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
1/25/2006
DOCUMENT NO
PC-2006-03
DOCUMENT NAME
PDR-502
NOTES
MITCHELL PEREIRA
NOTES 3
OFFICE BUILDING
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
60_ "fhe project developer's contractor(s~ shall obtain an encro achnzent permit from the City <br />Engineer prior to moving any construction equipment onto the site_ <br />6L The project developer shall bond 100% of the off-site improvements located in the public <br />right-ot=way in the form of a surety bond, letter of credit, or another instruxrxent approved <br />by the Crty Attor~icy. <br />Urban Stormwatar Design Requirements <br />62_ 71ie prof act shall comply with the Alameda Countywide NPD1=;S Permit #CA5002983I, a <br />copy of which is av ailablc at the City offices. <br />Ei3. The following requirements shall be incorporated into the prgject- <br />a_ The project developer shall submit a. final grading and drainage plan prepared by <br />a licensed civil engineer depicting all final grades and on-site drainage control <br />measures including bio-swalcs_ Irrigated bio-swales shall be redesigned as- <br />needed to the satisfaction of the City Engineer to optimize the ai rxou nt of the <br />storrrx water running of-I-the paved surface that enters the bio-swale at its most <br />upstream end_ 'I'bis plan shall be subject to the review and approval of the City <br />Engineer prior to the issuance of any building perrrxits_ <br />b_ Trash areas, dumpsters and recycling containers shall he enclosed and. roofed to <br />prevent water run-on to the area axed runoff from the area and to contain litter =irxd <br />trash, so that it is not dispersed by the wind or runoff during waste removal_ <br />These areas shall not drain to the storm drain system, but to the sanitary sewer <br />system and aii area drain shall be installed in the enclosure area, provi dixig a <br />structural control such as an oil/water separator or sand fi ltcr, or as otherwise <br />approved by the City Erxginaer. No other area shall drxi rt into the trash enclosure; <br />a berm shall be installed to prevent such drainage if found necessary by the Chief <br />Building Ott-ici al. A sign shall be posted prohibiting the duxrxping of hazardous <br />materials into the sanitary sewcr_ "llie project developer shall notify the Dublin- <br />San Ramon Services District (DSRSD~ upon installation of the sanitary <br />connection; a copy of this notification shall be provided to the Plaxzning <br />Department. <br />c. All metal roots, if used, shall be finished with rust-inhibitive paint_ <br />d. Roof drains shall discharge and drain away from the building foundation to an <br />unpaved area wherever practicable. <br />e. Any restaurant tenant for the building covered by this approval shall include a <br />contained area For cleaning mats, containers, and. equipmeu t. The wasYx area shall <br />be covered. or shall be designed to prevent runoff onto or $om the area. The area <br />shall be connected to the sanitary sewer, subject to approval by the DSRSD, or <br />shall be collected in a containment area and removed regularly by a disposal and <br />
The URL can be used to link to this page
Your browser does not support the video tag.