Laserfiche WebLink
52. <br /> <br />(h) <br /> <br />Fencing shall be constructed along the UPRR as determined necessary by the City <br />Engineer to reduce the likelihood that pedcsu'ians will cross the railroad tracks to <br />reach schools, shopping centers, or other attractions. <br /> <br />Vehicle Code Enforcement in Commercial/Office Centers. The Property Owner shall <br />seek City Council approval to allow on-site enforcement of applicable provisions oft.he <br />Vehicle Code within conunercia]Joffice centers' parking lots/drive aisles. Petitioning for <br />such approval shall precede occupancy of the centen <br /> <br />53. <br /> <br />H. Water and Wastewater <br /> <br />Backbone Water Distribution System. Property Owner shall be responsible for <br />constructing an on-site water transmission and distribution system in a manner <br />substantially consistent with the Specific Plan and as shown on Exhibits 11-14, <br />Preliminary Grading and Utility Plan, and connecting this system to the City's existing <br />potable water system. <br /> <br />(a) <br /> <br />The City's existing 12-inch and 16-inch water mains at Valley Avenue/Bernal <br />Avenue shall be extended as shown in Exhibits 11-14, Preliminary Grading and <br />Utility Plan, to connect to existing mains at Junipero Avenue/Case Avenue. A <br />12-inch main shall be extended easterly along Boreal Avenue and then through <br />the 4,000-square-foot lot streets to Street W, where it will stub out at Bernal <br />Avenue. Residential connections will be allowed to be made to this line. <br />Completion of these improvements shall satisfy the Project's off-site improvement <br />obligations. <br /> <br />(b) <br /> <br />Such improvements shall be designed and constructed consistent with City design <br />standards, subject to review and approval of the City Engineer. <br /> <br />(i) <br /> <br />No individual residential or commercial service laterals shall be permitted <br />to be connected to the 16-inch transmission line within the Valley Avenue <br />extension. Water mains of eight-inch and 12-inch size serving residential <br />and commercial uses are allowed to connect to this transmission line. <br /> <br />(ii) <br /> <br />Prior to approval of the MVTM, the Property Owner shall model the <br />proposed water system, showing pipe diameters, flows, water pressure and <br />fire flows, for review and approval of the City Engineer. The design <br />criteria for the water system shall be approved by the City Engineer prior <br />to the modeling. <br /> <br />Conditions of Approval Page 29 of 49 Revised August 21, 2000 <br /> <br /> <br />