My WebLink
|
Help
|
About
|
Sign Out
ORD 1806
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1806
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
9/11/2000 11:37:27 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
7/11/2000
DOCUMENT NO
ORD 1806
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(c) Sprinklers shall be provided in attics and between floors where floor/ceiling assemblies <br />consist of open web wood joists or trusses. <br /> <br />Exception: Townhouses with approved one-hour separations at the property line shall have <br />pilot spnnlders per (a) above. <br /> <br />CHAPTER 4-System Design - amended <br /> <br />Section 4-1.3- Water Demand is mended to reed: <br /> <br />(a.) One (1) to four (4) dwelling units. <br /> <br />The water demand for the system shall be determined by multiplying the design area of the <br />largest compamuent by the specified application rate. Additional demand is required for <br />domestic use as specified in Section 4-1.2. t (above). <br /> <br />CHAPTER 4-System Design - mended <br /> <br />Section 4-2.6 is added to read: <br /> <br />(a) Pilot fire sprinkler protection and fire detection shall be provided in all attic spaces. <br />Pilot fire sprinkler locations shall be near heat or fire sources, i.e., HVAC equipment, water <br />heaters, kitchen duct/erdmust penetratioes, or other electrical or gas fired equipment, etc. <br /> <br />(b) Pilot fire sprinkler sprig ups or risers shall be braced in accordance with pipe <br />manufacturers recommendations for vertical support and within 4 to 6 inches of the fire <br />sprinkler when the vertical riser exceeds 30 inches vertically. <br /> <br />Chapter 4-System Design - mended: .,, ~, <br />Section 4-6 Location of Sprinklers is amended to read: <br />Sprinklers shall be installed in all areas. <br /> <br /> Exception #1: Sprinklers may be omitted from bathrooms not exceeding 55 square feet (5.1 <br /> rn) with non-combustible fixtures. <br /> <br /> Exception #2: Sprinklers may be omitted from small closets where the least dimension does <br /> not exceed 3 feet. (0.9 M), the area does not exceed 24 square feet (2.2 m), and the walls and <br /> ceiling are surfaced with non-combustible materials. <br /> <br /> Exception #3: Sprinklers may be omitted from attics and crawl spaces which are not used or <br /> intended for living purposes or storage in buildings with no more than four (4) dwelling units, <br /> except pilot sprinklers are required as per section 4-2.6 (above). <br /> <br /> <br />