PC-93-49
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1993
>
PC-93-49
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:46 AM
Creation date
5/11/2005 3:59:22 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
8/11/1993
DOCUMENT NO
PC-93-49
DOCUMENT NAME
VTTM 6618
NOTES
BOULEVARD DEVELOPMENT/MOLLER RANCH
NOTES 3
SUBDIVIDE 198 AC INTO 99 SF LOTS/OPEN SPACE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Resolution No. PC-93-49 <br />Page 6 <br /> <br />a. The design of the water system shall insure that on a <br />average day, the water pressure does not fall below 40 <br />psi, at the peak hour the pressure doe not fall below 30 <br />psi, and with fire flow the pressure d es not fall below <br />20 psi, all of which shall be measur d at the meter. A <br />hydraulic analysis that models the wa er system shall be <br />submitted for review and approval of the city Engineer <br />with the submittal of the improveme t plans prior to <br />final map approval. <br /> <br />b. Where the static pressure exceeds 100 psi (elevations <br />below approximately 550 feet), ducti e iron pipe water <br />mains, saddles for service connecti ns and Class 200 <br />polyethylene services shall be used unless otherwise <br />approved by the city Engineer. <br /> <br />c. Pressure reduction valves (PRVs) sha 1 be installed at <br />the house to lower the water pressure to 80 psi, at all <br />homes where deemed necessary. No PRVs hall be permitted <br />at curbside. <br /> <br />d. Piping between the water meter and the PRV shall be 1.5- <br />inch minimum diameter and upgraded to chedule 80, or as <br />determined by the Chief Building Off ic ' al, to accommodate <br />the expected higher water pressures. A 1 service laterals <br />between the main and the meter shall b 1.5 inch minimum <br />diameter and shall be upgraded to accommodate the <br />additional water pressure, as dete ined by the city <br />Engineer. <br /> <br />e. The applicant shall install a reduce pressure station <br />near the intersection of A street and the EVA, if <br />determined necessary by the City Engin er, such that the <br />line in the EVA and "B" Court maybe a a lower pressure <br />zone. <br /> <br />f. <br /> <br />The exact location of the <br />Foothill road shall be approved <br />prior to the submittal of the <br />Foothill Road. <br /> <br /> <br />water mains in <br />he city Engineer <br />ovement plan for <br /> <br />g. <br /> <br />The size of the water main in "A" stree <br />Road and the EVA shall be approved by <br /> <br />between Foothill <br />he City Engineer. <br /> <br />17. Unless otherwise approved by the City Engin er the storm drain <br />line on "A" street near the intersection of Foothill Road <br />shall not dump into the drainage swale but shall continue to <br />Foothill Road and tie directly into the s orm drain culvert <br />crossing Foothill Road. The final storm d ainage design for <br />the area shown as the drain swale along th east side of "B" <br />Court shall be subject to review and app oval by the City <br />Engineer prior to approval of the final map. The final design <br />may include piped storm drainage systems r storm drainage <br />swales. <br />