Laserfiche WebLink
<br />105. The paving sections for the on-site parking and drive areas shall be designed on the basis <br />of an R-Value test and a traffic index to carry the anticipated traffic loads. This design <br />shall be subject to the approval of the Director of Building Inspection. The minimum <br />paving section shall be 2" A.C. on 6" of A.B. The minimum A.C. pavement slope shall <br />be 1 %. For pavement slopes of less than I %, the surface runoff shall be carried in a <br />concrete gutter to an acceptable point of discharge. The minimum slope for concrete <br />gutter shall be 0.5%. <br /> <br />106. A sanitary sewer sampling manhole shall be provided on each of the sanitary sewer <br />lateral from each building, unless otherwise waived by the Director of Building <br />Inspection. <br /> <br />107. Prior to issuance of a building permit, the developer shall pay the applicable Zone 7 and <br />City connection fees and water meter cost for any water meters, including irrigation <br />meters. Additionally, the developer shall pay any applicable Dublin San Ramon Services <br />District (DSRSD) sewer permit fee. <br /> <br />108. The developer shall pay any and all fees to which the property may be subject prior to the <br />issuance of building permits. The type and amount of the fees shall be those in effect at <br />the time the building permit is issued. <br /> <br />C. FIRE AUTHORITY <br /> <br />109. The development shall meet all requirements of the Pleasanton Fire Code (Chapter 20.24 <br />of the Pleasanton Municipal Code). <br /> <br />110. Approval for the number, type and location of fire hydrants shall be subject to the <br />approval of the Fire Chief and the City Engineer. <br /> <br />111. The developer shall ensure that fire protection facilities, including all surface roads, fire <br />hydrants, and a water supply capable of furnishing the required fire flow shall be installed <br />and serviceable prior to and during the time of construction. When alternate methods of <br />protection are as approved by the Fire Chief, this requirement may be waived or <br />modified. Proposed alternative methods of fire protection shall be submitted, in writing, <br />to the Fire Chief. Work on the alternative fire protection methods shall not start without <br />the approval of the Fire Chief. <br /> <br />112. All roads on the site are designated as fire apparatus access roads by the Fire Chief and <br />must be maintained in accordance with Section 10.201 of the Uniform Fire Code and be <br />accessible at all times from the start of construction until the project is completed. Curbs <br />must be painted red or "No Parking" signs provided as required by the vehicle code. <br /> <br />Case PUD-96-02 <br /> <br />Conditions of Approval <br /> <br />Page B-20 <br />