Laserfiche WebLink
10x Genomics Redevelopment Project CalEEMod Notes  <br />The following notes correspond with the note entries in the CalEEMod output files contained in this  <br />Appendix. Please refer to the CalEEMod output files to identify the corresponding note entry.  <br />Note 1. CO2 Intensity Factor adjusted to match PG&E 2017 emissions rates, the latest that are  <br />publicly available.1 The intensity factor utilized in the model is 210 pounds per megawatt‐ <br />hour delivered.  <br />Note 2. Land uses and sizes associated with development of the proposed project are drawn from  <br />information provided by the applicant dated October 22, 2020, and revised January 6, 2021.  <br />Land uses utilized in the model represent the following:  <br /> Construction Phase 1  <br /> Commercial > General Office Building > 80 x 1000sqft = Proposed 80,000 square feet of  <br />office space included in Phase 1 of the proposed project.  <br /> Industrial > Unrefrigerated Warehouse‐No Rail > 20 x 1000sqft = Proposed 20,000 square  <br />feet of warehouse, packaging, and distribution space included in Phase 1 of the proposed  <br />project.  <br /> Commercial > Research & Development > 50 x 1000sqft = Proposed 50,000 square feet of  <br />production laboratory space included in Phase 1 of the proposed project.   <br /> Parking > Parking Lot > 600 x Space = Proposed 600 surface parking spaces included in Phase  <br />1 of the proposed project.  <br /> Recreational > City Park > 8.09 x Acre = Remaining balance of project site assumed to be  <br />landscaping. This land use is included only in the construction models as it is intended to  <br />capture the need for total area graded during grading activities and the anticipated  <br />landscaping water consumption would be captured within the outdoor water consumption  <br />rates for the other land uses in the model.  <br /> Construction Phase 2  <br /> Commercial > General Office Building > 63.25 x 1000sqft = Proposed 63,250 square feet of  <br />office space included in Phase 2 of the proposed project.  <br /> Commercial > Research & Development > 51.75 x 1000sqft = Proposed 51,750 square feet of  <br />production laboratory space included in Phase 2 of the proposed project.  <br /> Parking > Unenclosed Parking Structure with Elevator > 1,168 x Space = Proposed 354,000  <br />square feet of parking structure space included in Phase 2 of the proposed project. Because  <br />the inclusion of an elevator with the parking structure was unknown at the time of this  <br />assessment, the parking structure was conservatively assumed to contain an elevator.  <br />  <br />1  Pacific Gas & Electric. 2018. Corporate Responsibility and Sustainability Report 2018. Website:  <br />http://www.pgecorp.com/corp_responsibility/reports/2018/assets/PGE_CRSR_2018.pdf. Accessed June 18,  <br />2020.  <br />Appendix A Page 7