My WebLink
|
Help
|
About
|
Sign Out
10 ATTACHMENTS
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2020
>
090120
>
10 ATTACHMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/7/2020 4:42:49 PM
Creation date
8/27/2020 9:20:51 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
9/2/2020
Document Relationships
10
(Message)
Path:
\CITY CLERK\AGENDA PACKETS\2020\090120
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Task 2.0 - PFAS Treatment Siting Evaluation <br />Task 2.1 - Well 5/6 and Well 8 Site Planning <br />The purpose of this task is to meet with the City's planning and operations departments to identify <br />preliminary site planning requirements for treatment facilities constructed at Well 5/6 and/or Well 8 sites. <br />Planning requirements include property line offsets, height restrictions, visual mitigations measures, <br />operational access criteria, and other items that may impact the site design. A major decision resulting from <br />this meeting shall be whether the treatment vessels and auxiliary equipment can be kept outdoors or shall be <br />housed inside a building. Since the Well 5/6 site is limited on space, preliminary site planning requirements for <br />treatment at City property located across the street from Well 5/6 shall also be identified. CONSULTANT shall <br />prepare meeting agenda, conduct the meeting, and prepare meeting minutes. <br />Task 2.2 - Infrastructure to Support Centralized Treatment at Well 8 <br />The purpose of this task is to identify infrastructure requirements to deliver water from Well 5/6 to Well 8 to <br />support centralized PFAS treatment at Well 8. The City is currently performing a Water Capacity Evaluation <br />(including hydraulic modeling) under a separate contract that will provide key information for this task. The <br />CONSULTANT tasks are summarized below with assistance by City, as noted. <br />• The CONSULTANT will perform a preliminary pipe alignment analysis (including desktop utilities <br />review) to determine preferred pipe route from Well 5/6 to Well 8 (and from Well 8 back to Well 5/6 <br />area if required). <br />• The City will perform a hydraulic evaluation to determine the pipe size, tie-in location, and pressure <br />requirements for delivering Well 5/6 treated water back into the distribution system; or if it can <br />combined with Well 8 treated water. This work will be performed under the City's Water Capacity <br />Evaluation Project. <br />• The CONSULTANT will perform a Well 5, 6, and 8 pump hydraulic evaluation to determine any <br />modifications needed to existing pumps to meet flow/head requirements of a centralized <br />treatment system. Evaluation includes determining if a booster station is needed at the Well 8 site. <br />• The CONSULTANT will provide estimates of capital and O&M costs associated with infrastructure <br />to support a centralized treatment system. These costs shall be factored into the life -cycle cost <br />analysis performed in Task 2.3. <br />A workshop with CONSULTANT, City staff, and City's consultant performing Water Capacity Evaluation <br />shall be conducted to review results and recommendations. CONSULTANT shall prepare meeting agenda, <br />conduct the meeting, and prepare meeting minutes. <br />Task 2.3 - PFAS Treatment Siting Evaluation and Process Design <br />The CONSULTANT will perform a PFAS treatment facility siting analysis to compare the alternatives of <br />dedicated PFAS treatment systems at Well 5/6 and 8 vs. a centralized treatment system at Well 8. The <br />analysis shall include a recommendation of the preferred alternative to proceed with for basis of design. <br />pw://Carollo/Documents/Client/CA/Pleasanton/_Proposals/Well 5, 6 and S PFAS Treatment and Well Improvements BODR/Exhibit A_Well 5, 6 and B PFAS Treatment and Rehabilitation Scope.dou <br />PAGE 4of10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.