PC-2003-10
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2000-2009
>
2003
>
PC-2003-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2007 9:30:23 AM
Creation date
3/23/2004 12:43:23 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
3/12/2003
DOCUMENT NO
PC-2003-10
DOCUMENT NAME
PUD-02-1D
NOTES
CITY OF PLEASANTON
NOTES 3
FIRE STATION
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
for subdrains in the vegetative filter/bio-swale areas. The final design of this area <br />shall be submitted to the City Engineer for review and approval before issuance of <br />anon-site permit and shall be shown on the final permit plan set. A maintenance <br />schedule shall be submitted to the City Engineer and to the Planning Director prior <br />to final inspection by the Planning Department. The maintenance schedule shall <br />cover turf mowing, the removal of sediment, erosion monitoring, and the replace- <br />ment of turf in advance of the rainy season. <br />These changes shall be shown on the on-site plan set and shall be submitted to the Plan- <br />ning Director for review and approval before issuance of a grading/on-site permit. <br />69. The trash enclosure area for the fire station shall be completely covered. An area drain <br />shall be installed in the enclosure area, which connects to the sanitary sewer. A structural <br />control such as an oil/water separator or sand filter shall be provided. No other area shall <br />drain into the trash enclosure; a bean shall be installed to prevent such drainage if found <br />necessary by the City Engineer/Chief of Building and Safety. These details shall be <br />shown on the building permit plan set to the satisfaction of the Planning Director before <br />issuance of a building permit. A sign shall be posted prohibiting the dumping of hazard- <br />ous materials into the sanitary sewer. The project developer shall notify the Dublin-San <br />Ramon Services District (DSRSD) upon installation of the sanitary connection; a copy of <br />this notification shall be provided to the Planning Department. <br />70. The project developer shall sweep or vacuum the parking lot and sidewalks a minimum <br />of once a month and shall prevent the accumulation of litter and debris on the site. Cor- <br />ners and hard to reach areas shall be swept manually. If sidewalks and/or the parking lot <br />are pressure washed, debris must be trapped and collected to prevent entry into the storm <br />drain system. No cleaning agent may be discharged into the storm drain. If any cleaning <br />agent or degreaser is used, wash water must be collected and discharged to the sanitary <br />sewer, subject to approval of the Dublin-San Ramon Services District (DSRSD). <br />71. The project developer shall label all on-site storm drain inlets with the wording, "No <br />Dumping -- Drains to Bay" using City-approved methods and materials. On-site storm <br />drain facilities shall be cleaned a minimum of twice a year as follows: immediately prior <br />to October 15 and once in January. Additional cleaning may be required if found neces- <br />sary by the City Engineer/Chief of Building and Safety. <br />72. The fuel dispensing area shall be covered with a canopy with the canopy downspouts <br />routed to prevent drainage flow across the fuel dispensing area. The fuel dispensing area <br />shall be located on a concrete surface, which shall extend at least eight feet from the face <br />of the fuel dispenser. The concrete slab surface surrounding the fuel dispensing area <br />shall be graded and constructed to prevent drainage flow across the fueling area, and to <br />drain towards the center of the dispensing area into a sump. The sump shall have the ca- <br />pacity to contain a normal spill as determined by the City Engineer. These details shall <br />PUD-0]-ID, Conditions ojApproval <br />per Planning Commission March 72, 2003 <br />Page 10 oj72 <br />