Laserfiche WebLink
BACKGROUND <br /> The subject property was rezoned to PUD-HDR in 1990 as part of a PUD development plan for <br /> 158 dwelling units on a combined project site totaling 12.76 acres. This project was never built <br /> and the PUD development plan expired in 1992, but the PUD rezoning did not expire. <br /> On November 11, 2015, Saravana Chilla, submitted a Preliminary Review application to <br /> demolish the existing home and construct four new single-family homes. Staff provided the <br /> applicant with comments discussing concerns related to the project density, architecture, and <br /> compatibility with the surrounding neighborhood. Staff suggested the applicant reduce the <br /> number of lots and revise the architecture and site layout to be consistent with the goals and <br /> policies of the Downtown Specific Plan. <br /> On June 8, 2017, the applicant submitted an application for PUD development plan (PUD-127) <br /> which reduced the proposal from four single-family homes to three. Staff continued to have <br /> concerns with the architecture, site design, and layout and provided comments on <br /> July 18, 2017. The applicant did not respond to the comments and the application was <br /> subsequently withdrawn in 2018. <br /> On October 19, 2018, the applicant submitted a new application for PUD development plan <br /> (PUD-133), to demolish the existing home and construct three new single-family homes. This <br /> application addressed the majority of staff's comments from the previously withdrawn PUD <br /> application, however, a few comments and concerns remain which will be discussed further in <br /> the Discussion Topics. <br /> The purpose of the work session is for the Planning Commission to review, comment and provide <br /> direction on the application. The work session also provides the public with an opportunity to <br /> review and comment on the proposed plan. No action on the project will be made at the work <br /> session. After the work session, the applicant will have the option to continue to move forward <br /> with the current proposal, modify the proposal based on the comments received, or withdraw the <br /> application. Should the applicant wish to proceed, the project will require Planning Commission <br /> action and a final decision by the City Council. A list of discussion topics and questions are <br /> included as Exhibit A to this report. <br /> AREA AND SITE DESCRIPTION <br /> The subject lot is located on the north side of Stanley Boulevard (aka Old Stanley), between <br /> Main Street/Santa Rita Road and First Street/Stanley Boulevard, as seen in Figure 1. <br /> PUD-133, 3987 Stanley Boulevard Planning Commission <br /> 2 of 11 <br />ing, and/or <br /> landscape plans. The fencing shall remain in place until final landscape inspection by the <br /> Landscape Architecture Division. Removal of such fencing prior to approval may result in a "stop <br /> work order." <br /> 110. PROJECT PLANS: The following statements shall be printed on the demolition, grading and <br /> landscape plans where applicable to the satisfaction of the City Landscape Architect prior to <br /> issuance of building permits: <br /> a. No existing tree may be trimmed or pruned without prior approval by the City <br /> Landscape Architect. <br /> b. Utilize best efforts to locate any new utility trenches outside of the existing canopy of <br /> the trees to be saved. If this is not feasible, the applicant shall submit a report from a <br /> certified arborist acceptable to the City indicating trenching will not be detrimental to <br /> the health of the tree. <br /> c. Nothing may be stored within the dripline of the tree canopies. This includes <br /> equipment, oil, gas, chemicals, harmful materials, fill or storage. <br /> PUD-133 Planning Commission <br /> Page 17 of 18 <br />rading or subdivision permit, whichever occurs first. The City will retain the cash <br /> deposit until all work is substantially complete, all areas are stabilized, and all hazards are <br /> mitigated to the satisfaction of the Director of Engineering/City Engineer. <br /> PUD-133 Planning Commission <br /> Page 13 of 18 <br /> Page 12 of 18 <br />S: <br /> The applicant's California licensed geotechnical engineer shall inspect and approve the <br /> PUD-133 Planning Commission <br /> Page 9 of 18 <br />