Laserfiche WebLink
g. The applicant shall work with staff to design the street sections to provide <br />sidewalks on both sides of the streets by reducing the street width. Said <br />modification shall be subject to review and approval by the City Engineer, <br />Director of Planning and Community Development, and the Planning <br />Commission at the time of the tentative map review. <br />Except as noted above, said modifications shall be shown on the plans <br />submitted for issuance of building permits and/or the subdivision <br />improvements plans, as applicable, and shall be subject to review and <br />approval by the City Engineer prior to issuance of building permits for the <br />project. <br />69. The following changes shall be shown on the subdivision improvement plans: <br />a. The vertical to rolled curb transition shall be 5 -foot long minimum. <br />b. The "typical curb cut at the grassy swale" shall be modified to reduce the <br />width of the opening, as determined by the City Engineer. <br />C. There shall be a disconnect between the roof leader and the curb to allow <br />the low flows from the roof to be absorbed into the ground while allowing <br />larger flows to flow directly to the gutter. <br />Said modifications shall be subject to review and approval by the City Engineer <br />prior to issuance of building permits for the project. <br />70. The applicant shall work with staff to provide stormwater treatment design <br />solutions for the development, subject to the review and approval by the City <br />Engineer and Director of Planning and Community Development. <br />71. The water and gravity sanitary sewer mains shall be public and maintained by <br />the City. There shall be individual sanitary sewer and water laterals to each <br />dwelling unit. There shall be a two-way cleanout on the gravity sanitary sewer <br />lateral located at the back of the PSE. <br />72. All subdrains shall have a cleanout installed at the beginning of the pipe. The <br />bottom of the pipe shall terminate in a storm drain or other storm drain outfall <br />subject the approval of the City Engineer. The applicant's engineer shall submit <br />a final subdrain location map to the City Engineer prior to acceptance of the <br />Public Improvements. It shall be the responsibility of the homeowner to relocate <br />the subdrains if, during the excavation of a pool or other subsurface structure, the <br />subdrains are encountered. All owners within the subdivision shall receive notice <br />of the presence of these subdrains. The City Attorney shall approve said notice. <br />73. A sanitary sewer lateral connecting a building/house having a finished pad grade <br />less than one foot above the nearest up -stream publicly maintained sanitary <br />sewer manhole shall be required to install a backflow device on the building/ <br />house lateral in accordance with the requirements of the Uniform Plumbing <br />13 <br />