2. Fire sprinklers shall be provided in garages. Fire sprinklers shall be intermediate <br /> rated, quick response type, with a maximum coverage area of 130 square feet per <br /> sprinkler. <br /> R313.2 Large One- and Two-Family Dwelling Residential Sprinkler Systems. In <br /> addition to the requirements specified in R313.1, one- and two- family dwellings with a <br /> habitable floor area greater than 7,500 square feet shall have an automatic fire-sprinkler <br /> system designed to include all sprinklers within a compartment, up to a maximum of four <br /> sprinklers. <br /> 20.10.060 CRC Table R602.10.3(3) amended — Bracing Requirements based on <br /> Seismic Design Category. <br /> Table R602.10.3(3) footnote "e" is is amended to read as follows: <br /> e. Method CS-SFB and Method GB are not permitted, and the use of Method PCP is <br /> limited to one-story single family dwellings and accessory structures. <br /> 20.10.070 CRC Section R602.10.4.4 added — Limits on methods GB and <br /> PCP. <br /> Section R602.10.4 is amended to add section R602.10.4.4 to read as follows: <br /> R602.10.4.4 Limits on methods GB and PCP. Method GB is not permitted for use as <br /> intermittent braced wall panels, but gypsum board is permitted to be installed when required <br /> by this Section to be placed on the opposite side of the studs from other types of braced <br /> wall panel sheathing. The use of Method PCP is limited to one-story single family dwellings <br /> and accessory structures. <br /> 20.10.080 CRC Section R907.7 amended — Fire Classification. <br /> Section R902.1 is amended to read as follows: <br /> R902.1 Roofing covering materials. Roofs shall be covered with materials as set forth in <br /> Sections R904 and R905. A minimum Class B roofing shall be installed in the City of <br /> Pleasanton. Roofing required by this section shall be listed shall be tested in accordance <br /> with UL 790 or ASTM E108. <br /> 20.10.090 CRC Appendix J Section AJ102.4.1 amended — Energy efficiency. <br /> Section AJ102.4.1 is amended to be read as follows: <br /> AJ102.4.1 Energy efficiency. Replacement windows shall comply with the fenestration <br /> requirements in the California Energy Code, Title 24 Part 6. <br /> 20.10.100 CRC Appendix J Section AJ301.2 amended —Water closets. <br />
The URL can be used to link to this page
Your browser does not support the video tag.