Laserfiche WebLink
20.10.030 CRC Chapter 1 Division II deleted. <br /> Chapter 1 Division II is deleted and replaced by Chapter 20.04, the Pleasanton Building <br /> Administrative Code. <br /> 20.10.040 CRC Table R301.2(1) amended — Climate and Geographic Design <br /> Criteria. <br /> Table R301.2(1) is amended to read as follows: <br /> TABLE R301.2(1) <br /> CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br /> WIND DESIGN SUBJECT TO DAMAGE FROM ICE <br /> GROUND Wind- SEISMIC WINTER BARRIER AIR MEAN <br /> Special Frost FLOOD <br /> SNOW Speed° Topographic Wind borne DESIGN Weatherin a line Termite° DESIGN UNDER HAZARDS9 FREEZING ANNUAL <br /> LOAD (mph) effects" ' debris CATEGORY' g TEMP° LAYMENT INDEX' TEMPI <br /> Region zone' depth n REQUIREDh <br /> Do Ver y See foot o , <br /> N/A NO NO NO , Di, Negligible N/A 32 NO 2% 58.7 <br /> mph D2, E Heavy note g _ <br /> For SI: 1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. <br /> a. The weathering index for the City of Pleasanton is classified as"negligible". <br /> b. The City of Pleasanton does not require additional depth of footing below finish grade. <br /> c. The City of Pleasanton has a history of local subterranean termite damage. <br /> d. The City of Pleasanton is in the 85 mph wind speed zone. <br /> e. The outdoor design dry-bulb temperature for the City of Pleasanton was selected from the columns of 97'/2-percent values for <br /> winter from Appendix D of the International Plumbing Code. <br /> f. The City of Pleasanton is in Seismic design categories Do, D,, D2 and E. <br /> g. The date of the City of Pleasanton's entry into the National Flood Insurance Program: May 5, 1971. <br /> The date(s)of the Flood Insurance Study:August 3,2009.The panel numbers of all currently effective FIRMs adopted by the City <br /> of Pleasanton,as amended: <br /> Panel 06001C0304G;Panel 06001C0308G; Panel 06001C0309G;Panel 06001C0316G;Panel 06001C0317G; <br /> Panel 06001C0318G;Panel 06001C0319G; Panel 06001C0328G;Panel 06001C0336G;Panel 06001C0337G; <br /> Panel 06001C0339G;Panel 06001C0343G;Panel 06001C0460G;Panel 06001C0476G;Panel 06001C0480G;and <br /> Panel 06001 C0485G. <br /> h. The City of Pleasanton does not have a history of local damage from the effects of ice damming. <br /> i. The City of Pleasanton selected the 100-year(99%)value on the National Climatic Data Center data table"Air Freezing Index- <br /> USA Method(Base 32°)"at www.ncdc.noaa.gov/fpsf.html. <br /> j. The City of Pleasanton selected the mean annual temperature from the National Climatic Data Center data table"Air Freezing <br /> Index-USA Method(Base 32°F)"at www.ncdc.noaa.gov/fpsf.html. <br /> k. There is not any local historical data documenting structural damage to buildings due to topographic wind speed-up effects in the <br /> City of Pleasanton. <br /> I. The City of Pleasanton is not in a Special Wind Region. <br /> m. The City of Pleasanton is not in a Wind-borne debris zone. <br /> 20.10.050 CRC Section R313 amended—Automatic Fire Sprinkler Systems. <br /> Section R313 is deleted in its entirety and amended to read as follows: <br /> R313.1 Automatic Fire Sprinkler Systems. An automatic residential fire sprinkler system <br /> shall be designed and installed in accordance with NFPA 13D in all new one- and two- <br /> family dwellings and townhouses. In addition, the fire-sprinkler system shall be designed <br /> and sprinklers shall be installed in the following locations: <br /> 1. Attic shall be provided with intermediate temperature-rated residential fire sprinklers <br /> for detection coverage, and located at a spacing equivalent to 30 feet by 30 feet <br /> centers and a maximum distance of 15 feet from outside walls. <br />