b. Public sewer and water utility connections from the terminus of Staples <br /> Ranch Drive through Continuing Life Community's site (PUD -68) shall be <br /> required prior to occupancy of any building on site. PSEs shall be required. <br /> The location of the utility lines and PSEs shall be subject to the review and <br /> approval of the City Engineer. <br /> c. Unless waived by the City Engineer, prior to the issuance of a building <br /> permit, the public water and sewer line connections between Hendrick <br /> Automotive Group's site (PUD -57) and Continuing Life Community's site <br /> (PUD -68) shall be relocated approximately 280 feet north, generally <br /> between buildings A and B shown on Exhibit B of PUD -57. The trash <br /> enclosure currently located on the west side of the property between <br /> buildings A and B shall be relocated to allow for adequate access to the <br /> lines for maintenance, as determined by the City Engineer. The final <br /> location of the trash enclosure shall be subject to the review and approval of <br /> the City Engineer and Planning Manager, prior to the issuance of a building <br /> permit. <br /> d. A portion of the public water line loop shall be located in the private <br /> entrance road. The proposed 18- and 24 -inch storm drain lines shall be <br /> relocated to accommodate the relocation of the public water line loop. The <br /> location of the lines shall be subject to the review and approval of the City <br /> Engineer prior to the issuance of a building permit. <br /> e. The proposed 24 -inch storm drain line in the PSE on Stoneridge Drive shall <br /> be relocated northerly into the parking lot drive aisle by building F. The <br /> location of the storm drain line shall be subject to the review and approval of <br /> the City Engineer prior to the issuance of a building permit. <br /> f. Prior to the issuance of a building permit, sections A -A and B -B of the site <br /> plan shall be revised to show a swale in the landscape area off the edge of <br /> pavement to treat the low flow stormwater traveling off the main entrance <br /> roadway. Curbs and gutters shall be provided on the outside edge of <br /> pavement. The curbs shall have openings to allow stormwater into the <br /> swale. The location and design of the curb openings shall be subject to the <br /> review and approval of the City Engineer. <br /> g. The proposed bioswales (vegetated swales) within the on -site parking areas <br /> shall be modified to provide a subdrain system installed beneath the filtering <br /> media to collect any excess stormwater in the bioswale area. The design <br /> details of the vegetated swales, including the filtering material shall be <br /> approved by the City Engineer prior to the issuance of a building permit. <br /> h. Prior to the issuance of a building permit, the grading plan shall be revised <br /> such that all stormwater shall flow away from the trash enclosures, <br /> Conditions of Approval /PUD -57 <br /> Project - Specific Conditions <br /> 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.