My WebLink
|
Help
|
About
|
Sign Out
ORD 2003
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
2001 - 2100
>
ORD 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:22:01 PM
Creation date
7/2/2010 4:37:01 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
6/15/2010
DESTRUCT DATE
PERMANENT
DOCUMENT NO
ORD 2003
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
of the total water usage based upon the reading of the master meter. It will then be the <br /> responsibility of the MA to bill the individual lot owners for the differences between the <br /> City's master meter and the individual private water meters. <br /> 59. The master meter that the applicant is responsible for furnishing and installing shall be a <br /> "Fireline" type meter installed in an appropriately sized vault with an acceptable cover, <br /> each to be approved by the City Engineer. The sizing and manufacturer of said meter <br /> will be determined by the City Engineer but will take into consideration the need to <br /> accurately measure all domestic, irrigation and fire flows that are anticipated within the <br /> Yee development and any existing or new homes within the Fuller /Smathers <br /> development or property. In addition, the applicant will be responsible for furnishing and <br /> installing an "excess flow" type valve on the Fuller /Smathers private water system <br /> pipeline at a location and type acceptable to the City Engineer. The applicant shall be <br /> responsible for the cost of any additional telemetry equipment, wiring or SCADA <br /> improvements necessary to connect and properly monitor the aforementioned <br /> equipment within the City's existing SCADA system. <br /> 60. A maintenance agreement for the water main including the individual Pressure Reducing <br /> Valves (PRV) on the water services shall be submitted for review and approval of the <br /> City Attorney and the City Engineer prior to the approval of the parcel map. The <br /> agreement shall include the provision, if the City of Pleasanton is contacted by the <br /> residents or the Maintenance Association (MA) regarding the maintenance and /or repair <br /> of the private water line and the City water crews are called out to investigate the <br /> problem, if it is determined that the City's public water supply is not responsible for the <br /> problem, the resident or the MA shall be responsible for the cost of City water crews on <br /> a time and materials basis. <br /> 61. The water main shall be designed, installed and inspected in accordance with City <br /> Standards including the installation of pressure reducing stations as determined by the <br /> City Engineer to reduce and maintain the water main pressure at or below 120 psi. The <br /> specifications for the water main shall be submitted with the Improvement Plans <br /> submitted with the parcel map for approval of the City Engineer. <br /> 62. Unless otherwise approved by the City Engineer, the water mains for this development <br /> shall be constructed of welded steel pipe or of ductile iron pipe with T.R. -flex fittings. <br /> The applicant shall retain a certified inspection firm to inspect the pipe installation and to <br /> certify the pipe welds or the flex fittings to the satisfaction of the City Engineer before <br /> closing the trench. The entire water main system shall be protected from corrosion with <br /> a Cathodic Protection System (CPS), designed and inspected by a corrosion engineer <br /> registered in the State of California to the satisfaction of the City Engineer. The <br /> applicant shall provide copies of the inspection reports to the City Engineer before <br /> closing the trench. <br /> 63. The applicant shall design and install the water main for this development to provide for <br /> the extension of a private water main to the lots of Tract 6275 to the south. The details <br /> shall be shown on the Improvement Plans submitted with the parcel map for the review <br /> and approval by the City Engineer and the Planning Division. The applicant of this <br /> development shall not object to the developer of Tract 6275 from annexing into the <br /> maintenance agreement for the water main between Fuller /Smathers and this applicant <br /> (Yee). <br /> 16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.