My WebLink
|
Help
|
About
|
Sign Out
ORD 1869
City of Pleasanton
>
CITY CLERK
>
ORDINANCES
>
1801 - 1900
>
ORD 1869
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2023 4:24:07 PM
Creation date
10/25/2002 4:11:53 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
ORDINANCES
DOCUMENT DATE
10/1/2002
DOCUMENT NO
ORD 1869
DOCUMENT NAME
BUILDING CODES
Tags
Ordinance
Description:
Ordinance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) Multifamily dwellings permitted to be of Types III, IV, <br />and V construction except as prohibited in 336-5. <br /> <br />(3) Other structures permitted to be of Types III, IV, and V <br />construction except as prohibited in Article 336-5. Cables <br />shall be concealed within walls floors, or ceilings that <br />provide a thermal barrier of material that has at least a 15- <br />minute finish rating as identified in listings of fire-rated <br />assemblies. <br /> <br />(4) Cable trays, where the cables are identified for <br />such use <br /> <br />FPN: See Section 310-10 for temperature limitation of <br />conductors. <br /> <br />(a) Type NM. Type NM cable shall be permitted for both <br /> exposed and concealed work in normally dry location. <br /> It shall be permissible to install or fish type NM cable <br /> in air voids in masonry block or tile wall where such <br /> walls are not exposed or subject to excessive moisture <br /> or dampness. <br />(b) Type NMC. Type NMC cable shall be permitted as <br /> follow: <br /> <br />(1) For both exposed and concealed work in dry, <br /> moist, damp, or corrosive locations <br />(2) In outside and inside walls of masonry block <br /> or tile <br />(3) In a shallow chase in masonry, concrete, or <br /> adobe protected against nails or screws by a <br /> steel plate at least 1/16-in. (1.59 mm) thick, <br /> and covered with plaster, adobe, or similar <br /> finish <br /> <br />(c) Type NMS. Type NMS cable shall be permitted for <br />both exposed and concealed work in normally dry location. <br />It shall be permissible to install or fish Type NMS cable in <br />air voids in masonry block or tile walls where such walls <br />are not exposed or subject to excessive moisture or <br />dampness. Type NMS cable shall be used as permitted in <br />Article 780. <br /> <br />20.20.026 Article 625-29 (d) 1 - Added- Table Values for Ventilation. <br /> <br />59 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.