Laserfiche WebLink
44. The applicants shall submit a building survey and/or record of survey and a site <br /> development plan in accordance with the provisions of Chapter 18.68 of the Municipal <br /> Code of the City of Pleasanton. These plans shall be approved by the Director of <br /> Building Inspection prior to the issuance of a building permit. The site development plan <br /> shall include all required information to design and construct site, grading, paving, <br /> drainage, and utilities. Specific items to be indicated on the site development plan <br /> necessary to construct the improvements are to be in accordance with the City of <br /> Pleasanton Private Development Design Guidelines adopted April 15, 1986. <br /> <br />45. The applicants shall submit a pad elevation certification prepared by a licensed land <br /> surveyor or registered civil engineer to the Chief Building Official and Planning Director, <br /> certifying that the pad and building locations (setbacks) are pursuant to the approved <br /> plans, prior to receiving a foundation inspection for the structure. <br /> <br />46. The paving sections for the on-site parking and drive areas shall be designed on the basis <br /> of an R-Value test and a traffic index to carry the anticipated traffic loads. This design <br /> shall be subject to the approval of the Director of Building Inspection. The minimum <br /> paving section shall be 2" A.C. on 6" of A.B. The minimum A.C. pavement slope shall <br /> be 1%. For pavement slopes of less than 1%, the surface runoff shall be carded in a <br /> concrete gutter to an acceptable point of discharge. The minimum slope for concrete <br /> gutter shall be 0.5%. <br /> <br />47. A sanitary sewer sampling manhole shall be provided on each of the sanitary sewer <br /> lateral from each building, unless otherwise waived by the Director of Building <br /> Inspection. <br /> <br />48. Prior to issuance of a building permit, the applicants shall pay the applicable Zone 7 and <br /> City connection fees and water meter cost for any water meters, including irrigation <br /> meters. Additionally, the developer shall pay any applicable DSRSD sewer permit fee. <br /> <br />49. Building and sims plans are to be submitted to the Building Department on computer disk <br /> in a format approved by the Director. Digitized information shall be submitted before <br /> requesting a final inspection and should reflect as-built sims and architectural information <br /> as approved by the Director. <br /> <br />50. The applicants shall submit two copies of the site soils report to the Director of Building <br /> Inspection. If necessary, a third party peer review shall be completed at the applicants' <br /> expense prior to issuance of a grading permit. <br /> <br /> <br />