Laserfiche WebLink
250 square-foot backyard patios. Lack of group open space is mitigated by the close proximity <br />of Veterians Park to the subject site. The project will also be subject to the City's park <br />dedication fee requirements. <br />Existing Trees <br />An arborist report was prepared for the five trees on the subject site (Attachment 5: Exhibit C); <br />two Black Walnut trees (No. 22 and 23) and one English Walnut tree (No. 24) along the eastern <br />portion of the driveway and one Black Walnut tree (No.26) and one English Walnut tree (No. <br />25) in the southeast portion of the property. Although the arborist report recommends removal <br />of tree No. 24, staff does not agree with the conclusion that the tree needs to be removed and has <br />added a condition of approval that the tree shall not be removed. The City's Landscape <br />Architect has reviewed the report and conducted a site inspection and agrees with staff s <br />recommendation, therefore, the three trees located along the driveway shall be retained. <br />Given the proximity to unit 2 and the structural issues of the two trees located at the rear of the <br />property, tree No. 25 and 26, would have to be removed. The trees would not be able to sustain <br />the impacts of construction as walnut trees are sensitive to construction activities, thus, it is <br />highly unlikely that the trees would survive. Therefore, the applicants shall pay into the Urban <br />Forestry Fund in the amount of the two trees total appraised value ($4,000.00). The applicants <br />will also be required to post a bond in the amount of the three trees that shall be retained <br />($17,470). <br />Staff has conditioned the project and provided the Arborist report as Attachment 5. <br />Noise Study <br />Given the sites close proximity to the Union Pacific Railroad tracks, approximately 280 feet, a <br />noise study was prepared by Wilson, Ihrig & Associates, Inc. (Attachment 6). The study <br />provides a comparison of the noise levels to the applicable City standards and recommends <br />mitigation measures for the project to meet the City's interior Day-Night Average Sound Level <br />(DNL) goal of 45dBA and the interior single-event noise level goal of SOdBA. The study <br />indicates that the DNL can be met by using high-performance dual-pain windows. For the <br />single event levels to be met, the study recommends Sound Transmission Class (STC) rated <br />windows. Interior noise levels can be mitigated by additional measures, such as increased sound <br />insulation in the walls of the structure. A condition of approval has been added to ensure that <br />recommendations in the noise study are implemented. <br />Green Building <br />All new residential projects are required to include green building measures in the design of new <br />homes. The three units shall achieve a minimum of 50 total points and the minimum <br />requirements in each category (Community, Energy, Indoor Air Quality/Health, Resources, and <br />Water) required for a City Certified Rating. The project has been conditioned to require the <br />PUD-76, Morales /White Planning Commission <br />Page 7 of 11 <br />