Laserfiche WebLink
85. All building and/or structural plans must comply with all codes and ordinances in <br />effect before the Building and Safety Division will issue permits. <br />86. The project developer shall submit a final map, a building survey, or record of <br />survey and a site development plan in accordance with the provisions of <br />Chapter 18.68 of the Municipal Code of the City of Pleasanton. These plans <br />shall be approved by the Chief Building Official prior to the issuance of a building <br />permit. The site development plan shall include all required information to design <br />and construct site, grading, paving, drainage, and utilities. Specific items to be <br />indicated on the site development plan necessary to construct the improvements <br />are to be in accordance with the City of Pleasanton Private Development Design <br />Guidelines adopted April 15, 1986. <br />87. The applicant shall submit 3 full-size sets of construction plans (wet-stamped and <br />signed), 2 sets of the necessary structural and Title 24 calculations, 2 copies of a <br />site specific soils report, and the completed Building Permit Questionnaire to the <br />Building and Safety Division, along with the necessary fees, to initiate the City's <br />plan check process. <br />88. A sanitary sewer sampling manhole shall be provided on any new sanitary sewer <br />lateral from the building, unless otherwise waived by the Chief Building Official. <br />89. All retaining walls higher than four feet (4' 0") from the top of the wall to the <br />bottom of the footway shall be constructed of reinforced concrete or shall be an <br />approved crib wall type. Calculations signed by a registered civil engineer shall <br />accompany the wall plans. <br />90. Building and situs plans are to be submitted to the Building and Safety Division <br />on computer disk in a format approved by the Director. Digitized information <br />shall be submitted before requesting a final inspection and should reflect as-built <br />situs and architectural information as approved by the Director. <br />Police Department Requirements <br />91. The area of the development shall be tested for strength and clarity of signal to <br />and from the area for City emergency services communications including, but not <br />limited to, City eight-hundred megahertz (800 MHz) trunked radio, Livermore- <br />Pleasanton Fire Services radio, Alameda County eight-hundred megahertz <br />(800 MHz) trunked radio, CLEMAR/ Police Dispatch, and the current police <br />mobile data system, unless waived by the Police Department, City of Pleasanton. <br />Expert opinions may be required in anticipation of communications difficulties <br />inside or around large structures. Mitigation plans of less than acceptable <br />communications shall be submitted to the satisfaction of the Police Department <br />prior to approval and shall be financed by the project developer immediately <br />upon approval. <br />14 <br />