My WebLink
|
Help
|
About
|
Sign Out
PC-87-130
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1980-1989
>
1987
>
PC-87-130
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2008 10:35:29 AM
Creation date
3/27/2008 3:20:20 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
12/9/1987
DOCUMENT NO
PC-87-130
DOCUMENT NAME
UP-87-52
NOTES
SYLVAN LEARNING CTR/PORTFOLIO PROPERTIES
NOTES 2
APPLIED FOR PERMIT TO ESTABLISH LEARNING CTR
NOTES 3
3015 HOPYARD ROAD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Resolution No. PC-87-129 <br />December 9, 1987 <br />submittal of the final map and improvement plans. This <br />report shall contain specific recommendations concerning the <br />procedures and methods to be used to preserve heritage trees <br />adjacent to or within construction areas on-site and with <br />thirty feet of the interim improvements for Dublin Canyon <br />Road. Information submitted shall include the tree species, <br />trunk diameter at breast height, dripline diameter or <br />radius, existing ground elevation at the base of the tree, a <br />ground profile where required, a statement regarding the <br />health of the tree, a recommendation for preservation or <br />removal, and site specific recommendations for preservation. <br />51. The radius of the curve in the private <br />unit 16 and unit 19 shall be increased <br />52. The storm drain inlets at the terminus <br />drainage swales shall be designed to tl <br />City Engineer to provide positive flow <br />to avoid overflow. <br />drive adjacent to <br />to approximately 35'. <br />of the concrete <br />ze satisfaction of the <br />into the inlets and <br />53. The approval for the grading and drainage plan shall be <br />withheld pending final design and until the developer has <br />demonstrated to the satisfaction of the City Engineer that <br />the requirements of the City and of Chapter 70, UBC have <br />been met. <br />54. Any on-site or off-site change in, roadway, sidewalk or pad <br />elevations in excess of 0.5' shall require special approval <br />from the City Engineer and revised plans. <br />55. The proposed culvert at the entrance drive shall be revised <br />to provide an improved channel approach angle at the <br />entrance. <br />56. The proposed grading alignment for the slope bank between <br />Dublin Creek and the proposed swimming pool shall be revised <br />to the satisfaction of the City Engineer to provide a less <br />abrupt channel bend. <br />57. Prior to the City Council approval of the final map for this <br />development, the applicant shall provide the following items <br />to the City for Fire Department base mapping purposes: <br />a. Two mylar copies each of a 1"-100' scale map and a <br />1"=250' scale map of the development showing only the <br />following map elements: <br />(1) Street right-of-way lines <br />(2) Property (or lot) lines <br />(3) Face of curb lines <br />b. one mylar copy each of a 1"-100' scale map and a <br />1"=250' scale map of ,the development showing the <br />following: <br />- 10 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.