My WebLink
|
Help
|
About
|
Sign Out
14
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2007
>
120407
>
14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2007 2:27:21 PM
Creation date
11/28/2007 12:27:52 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
15 Y
DOCUMENT NO
14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2308.12.4. Braced wall panels shall be distributed along the length of the braced wall <br />line and start at not more than 8 feet (2438mm) from each end of the braced wall line. <br />Panel sheathing joints shall occur over studs or blocking. Sheathing shall be fastened <br />to studs, top and bottom plates and at panel edges occurring over blocking. Wall <br />framing to which sheathing used for bracing is applied shall be nominal 2 inch wide [1 '/2 <br />inch (38 mm)] or large members. <br />Braced wall panel construction types shall not be mixed within a braced wall line. <br />Braced wall panels required by Section 2308.12.4 may be eliminated when all of the <br />following <br />requirements are met: <br />1. One story detached garage Group U occupancies not more than 25 feet in depth or <br />length. <br />2. The roof and three enclosing walls are solid sheathed with'/2-inch nominal thickness <br />wood <br />structural panels with 8d common nails placed 3/8 inches from panel edges and spaced <br />not <br />more than 6 inches on center along all panel edges and 12 inches on center along <br />intermediate framing members. Wall openings for doors or windows are permitted <br />provided a minimum 4 foot wide wood structural braced panel with minimum height to <br />length ratio of 2 to 1 is provided at each end of the wall line and that the wall line be <br />sheathed for 50% of its length. <br />(Balance of section to remain). <br />20.08.042 -This Section is Deleted. <br />20.08.043 Section 903.2 amended -Where Required. <br />Section 903.2 Where Required of the California Building Standards Code 2007 Edition <br />(24 C.C.R.), and including by reference the International Building Code, 2006 Edition, <br />Volumes 1 and 2, is amended to read as follows: <br />903.2 An automatic fire extinguishing system or other approved fire suppression <br />system(s) shall be installed as follows: <br />1. In every building where the floor and basement area exceeds 8000 square feet. <br />Exceptions: <br />1. Group U, Division 1 private garages of 1,000 square feet or less. <br />2. Group U, Division 2 Occupancies. <br />41 <br />
The URL can be used to link to this page
Your browser does not support the video tag.