Laserfiche WebLink
inspector, for failure to provide access on the date for which inspection is requested, or <br />for deviating from plans requiring the approval of the Building and Safety Official. <br />To obtain a re-inspection. the applicant shall first file an application therefor in writing <br />upon a form furnished for that purpose, and pay the re-inspection fee in accordance <br />with the Fees and Charge as set forth in the Pleasanton Municipal Code. In instances <br />where re-inspection fees have been assessed, additional inspection of the work will not <br />be performed until the required fees have been paid. <br />SECTION 306A -SPECIAL INSPECTIONS <br />306A.1 General. In addition to the inspections required by Section 305A.5, the owner <br />or the engineer or architect of record acting as the owner's agent shall employ one or <br />more special inspectors who shall provide inspections during construction as detailed in <br />Section 1704 of the building code. <br />EXCEPTION: The Building and Safety Official may waive the requirement or the <br />employment of a special inspector if the construction is of a minor nature. <br />SECTION 307A -STRUCTURAL OBSERVATION <br />Structural observation shall be provided when so designated by the architect or <br />engineer of record, or when such observation is specifically required by the Building <br />and Safety Official. <br />The owner shall employ the engineer or architect responsible for the structural design, <br />or another engineer or architect designated by the engineer or architect responsible for <br />the structural design, to perform structural observation as defined in this section. <br />Observed deficiencies shall be reported in writing to the owner's representative, special <br />inspector, contractor and the Building and Safety Official. The structural observer shall <br />submit to the Building and Safety Official a written statement that the site visits have <br />been made and identifying any reported deficiencies which, to the best of the structural <br />observer's knowledge, have not been resolved. <br />Structural observation does not include or waive the responsibility for the inspections <br />required by Section 305A.5, 1704 of the building code or other sections of this code. <br />SECTION 308A -CONNECTION TO UTILITIES <br />308A.1 Energy Connections. Persons shall not make connections from a source of <br />energy, fuel or power to building service equipment or other service equipment which is <br />regulated by the technical codes and for which a permit is required by this code, until <br />approved by the Building and Safety Official. <br />308A.2 Temporary Connections. The Building and Safety Official may authorize the <br />temporary connection of the building or other service equipment to the source of <br />31 <br />