PC-88- 88
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1980-1989
>
1988
>
PC-88- 88
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2008 10:35:22 AM
Creation date
9/25/2007 12:23:17 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
8/10/1988
DOCUMENT NO
PC-88-88
DOCUMENT NAME
PUD-85-15-2D
NOTES
CURRIN CONSTRUCTION CO. AND TIMM DEVELOPMENT, INC.
NOTES 2
FINAL DEVELOPMENT PLAN APPROVAL FOR 80LOTSINGLE FAMILY DEVON APPROX 262 ACRE SITE
NOTES 3
W. SIDE FOOTHILL RD. 3,100 FEET S. OF BERNAL AVE.-FOOTHILL RD. INTERSECTION
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
17. Interim measures for achieving the intent of the recommenda- <br />tions of the soils and geologic report following street im- <br />provements but prior to house construction shall be developed <br />by the project's engineering geologists/soils engineers for <br />review and approval by the City at the tentative map stage. <br />18. Prior to filing the tentative map, a preliminary utility plan <br />shall be designed which shows the nature and extent of damage <br />to native vegetation required to install and provide mainte- <br />nance to utilities. This utility plan shall be designed to <br />minimize damage to native vegetation. The final improvement <br />plan for storm drainage and subdrains shall indicate how <br />natural watering of native species will be maintained while <br />meeting the dewatering requirements of the soils engineering <br />report; these plans shall be subject to the approval of the <br />City Engineer. <br />19. Geologic/soils studies investigating the potential hazard to <br />the project of off-site mud flows shall be prepared to the <br />satisfaction of the Planning Director prior to filing a final <br />map. Any remedial work to be done on the City's property <br />(Bernal Park) shall be done, if authorized by the City, and at <br />the developer's expense. If authorization to remedy the <br />hazard is not given, the project shall be redesigned, to the <br />satisfaction of the Planning Director, to remove dwellings <br />from the potentially hazardous area. <br />20. Final design of the recreation area/clubhouse shall be subject <br />to review and approval by the Design Review Board. <br />21. The private, on-site streets shall be constructed as shown on <br />the cross-sections of Exhibit 11 of the final development <br />plans, except the minimum street width shall be 29 feet or as <br />otherwise approved by the City Engineer. These streets shall <br />be maintained by the property owners. Streets shall allow <br />parking on only one side, and shall be signed to allow City <br />enforcement, if necessary. <br />22. Unless otherwise approved by the City Engineer, the minimum <br />radius of all cul-de-sac bulbs shall be 45 feet. <br />23. The proposed paved drainage ditches shall be constructed of <br />concrete. <br />24. The length of the vertical curves on project streets shall be <br />designed to the satisfaction of the City Engineer, <br />particularly in those areas where the street grade is over 10 <br />percent. <br />