My WebLink
|
Help
|
About
|
Sign Out
PC-2007-25, PTR-7813, AUSTIN
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2000-2009
>
2007
>
PC-2007-25, PTR-7813, AUSTIN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2008 10:37:44 AM
Creation date
8/30/2007 12:12:03 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
5/23/2007
DESTRUCT DATE
15 Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />maintain 14feet clear area above the roadway (20 feet). The water <br />and sewer laterals and storm drain system within the driveways <br />shall be private and maintained by the individual property owners or <br />HOA. <br /> <br />b. The Typical Private Driveway Section (without bridges): <br />The driveway section shall be a minimum of 16 feet wide paved <br />surface with 2 feet of class II aggregate base rock on both sides of <br />the driveway unless otherwise approved by the Fire Marshall. The <br />structural section of the driveway shall support the Fire apparatus <br />and maintenance vehicle as determined by the City Engineer. The <br />minimum outside radius of the driveway shall be 55 feet. The <br /> p <br />maximum grade of the driveway shall be 15ercent except at <br />driveway intersections where the grade shall not exceed 7 percent. <br /> <br />The landscaping shall be trimmed back to maintain 14feet clear <br />area above the roadway (20 feet). The water and sewer laterals <br />and storm drain system within the driveways shall be private and <br />. <br />maintained by the individual property owners or HOA <br /> <br /> <br />6. The typical lot side slope shall be 3:1 maximum, unless otherwise <br />approved by the City Engineer. <br /> <br /> <br />7. The concrete V-ditch located between the lots shall extend down the slope <br />and tie into the V-ditch along the north and south sides of the development <br />unless otherwise approved by the City Engineer. <br /> <br />8. The homeowners association shall maintain the Filterra stormwater <br />filtering system unless otherwise approved by the City Engineer. <br /> <br />9. The subdivider’s engineer shall demonstrate to the satisfaction of the City <br />Engineer that the Filterra stormwater filtering system will capture a <br />minimum of 0.2 inches per hour storm with a 15 percent street grade. <br /> <br />10. The northeasterly curb return at the intersection of Austin Place and the <br />City parking lot the radius shall be adjusted to accommodate the fire truck <br />otherwise approved by the City Engineer <br /> <br />11. If the existing home is to remain the overhead utilities serving the home <br /> <br />shall be underground as part of the subdivision improvements. The <br />subdivider shall convert these homes from overhead services to <br />underground. <br /> <br />12. The curb and gutter of all streets within the development, shall have <br />subdrains installed at either the back of curb or lip of gutter at the <br />discretion of the City Engineer. This detail shall be shown on the <br /> <br />2 <br /> <br />