My WebLink
|
Help
|
About
|
Sign Out
2110
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1980-1989
>
1981
>
2110
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2008 10:34:27 AM
Creation date
7/26/2007 2:23:33 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
12/16/1981
DOCUMENT NO
2110
DOCUMENT NAME
PUD-81-22
NOTES
DAON CORPORATION AND STONESON DEVELOPMENT CORP
NOTES 2
REZONING
NOTES 3
BOUNDED BY STONERIDGE DR, STONERIDGE MALL RD, AND I-580 AND 680
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
47. The proximity of the Stoneridge Mall Road intersection with <br />the first interior median break on both streets may be <br />.insufficient to provide for adequate weaving and turning <br />movements and turn lane storage. This shall be subject to <br />future detailed review. <br />4S'. The angle point in RW-1 shall be revised to provide for <br />a large radius curve compatible with an approved design speed. <br />49. The cul-de-sac areas of RW-1 and RW-2 shall be subject to <br />future detailed review with regard to the curb radii and <br />specifically with regard to the protrusion of the structure <br />of H-1 into the street area. <br />50. The cross-section of the two public entrance drives, RW-1 <br />and RW-2, shall be as follows unless otherwise approved by <br />the City Engineer: <br />A. a minimum ten foot wide park strip from south <br />property line to face curb (with side walk if required.); <br />B. twenty-seven feet from face of curb to face of <br />median curb to provide for a 14' and a 13' travel <br />lane; <br />C. an eighteen foot wide median to provide for 12' <br />left turn lanes, proposed median landscaping, and <br />utilities; <br />D. twenty-seven feet from face of median curb to face <br />of curb;. <br />E. ten feet minimum from face of curb to north property <br />line. <br />The total curb to curb width shall be 72 feet. The total <br />right-of-way width shall be 92 feet or as otherwise approved <br />by the City Engineer. <br />51. The interior, residential drive shall be designed to meet <br />the requirements of the Fire t4arshall and the City Engineer <br />with respect to width and minimum curb radii and shall be <br />designed as a continuous loop road unless otherwise approved <br />by the City Engineer. <br />52. That the developer submit an overall utility master plan <br />and an overall circulation plan as part of the tentative <br />map submittal. <br />