My WebLink
|
Help
|
About
|
Sign Out
2003
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1980-1989
>
1981
>
2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2013 1:59:08 PM
Creation date
7/24/2007 10:37:08 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
5/20/1981
DOCUMENT NO
2003
DOCUMENT NAME
MAP NO. 4807
NOTES
MIKE HARRIS
NOTES 2
RESIDENTIAL SUBDIVISION OF 16 UNIT CONDOMINIUM COMPLEX
NOTES 3
E. OF SANTA RITA RD. AND N. OF FIRE STATION NO. 3
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Tentative Map, Tract 4807 <br />Page 3 <br />16. That approval of the storm drainage system be withheld <br />pending final design and until the developer has demon- <br />strated to the satisfaction of the City Engineer that <br />the system is adequate, connects to an approved point of <br />discharge, meets any and all applicable requirements of <br />the Alameda Flood Control District, meets any and all <br />applicable requirements of the Federal Emergency <br />Management Flood Hazard Program, and meets the imme- <br />diate and lon range requirements of this development <br />and all upstr~am areas intended to be drained through <br />this tract. <br />17. That electric power distribution, gas distribution, <br />communication service, and any required alarm systems be <br />installed underground in a joint utility trench unless <br />otherwise specifically approved by the City Engineer. <br />18. That the developer be responsible for the installation of <br />the street lighting system within the development. The <br />street lights shall be 70 watt, high pressure sodium vapor <br />units mounted on galvanized steel poles with poured in <br />place bases, on the LS-1C schedule per City requirements <br />and P.G.&E. standard details unless otherwise specifically <br />approved. Approval for the number, location, and type <br />of electroliers shall be withheld pending final design and <br />review by the City Engineer. <br />lg, That in-lieu park dedication fees be collected by <br />the City prior to approval of the final map at the <br />* rate then in effect and for the total number of <br />residential lots in the final map, unless this <br />requ has. been otherwise satisfied. <br />20, That any existing assessment district, which the property <br />may be subject to, be cleared prior to the approval of the <br />final map or the developer will cause a segregation to be <br />completed in conjunction with the final map. <br />21. That the developer submit a refundable cash bond for <br />hazard control prior to approval of the final map. The <br />amount of this bond will be determined by the City <br />Engineer. (Approximately $100 per lot - $2500 minimu3n). <br />22. That the developer submit a detailed street tree planting <br />plan. <br />*amended at 5/20/81 Planning Commission meeting. <br />
The URL can be used to link to this page
Your browser does not support the video tag.