Laserfiche WebLink
20.08.048 <br />response time, as determined by <br />the Fire Chief, from a City fire <br />station. <br />3. Any structure in any area or <br />location determined by the Fire <br />Chief to be a high fire hazard. <br />High fire hazard area shall be <br />defined as those areas beyond five <br />minutes driving time of fire <br />apparatus from the fire station <br />serving those particular districts; <br />or areas determined by the Fire <br />Chief to be either high hazard <br />areas or extreme hazard areas <br />based on steepness of slope and/or <br />fuel loadings from combustible <br />plant materials as set forth in the <br />Safety Element of the General <br />Plan. <br />(Ord. 1778 § 2, 1999; Ord. 1669 § 2, <br />1995) <br />20.08.049 City Of Pleasanton <br />Sprinkler Standard 9-3 <br />Amended: <br />UBC Section 902-Standards of Qual- <br />ity <br />1. Fire-Extinguishing system <br />1.2 UBC Standard 9-3 -amended to <br />reference NFPA 13D-1999 Ed. <br />UBC Standard 9-3 is amended to <br />adopt National Fire Protection Asso- <br />ciation (NFPA) 13D-1999 Edition. <br />This Standard includes installation of <br />fire sprinkler systems in buildings up <br />to fifteen (15) units and up to a <br />maximum of twelve thousand <br />(12,000) square feet maximum. <br />Chapter 1-General Information <br />amended - <br />Section 1-1 Scope is amended to <br />read: <br />This standard describes the require- <br />ments for the mechanical and perfor- <br />mance properties of the sprinkler <br />itself. It also describes the require- <br />ments for the installation of the <br />complete sprinkler system for resi- <br />dential occupancies up to fifteen (15) <br />units or twelve thousand square feet <br />(12,000) maximum. <br />Chapter 1-General Information - <br />amended <br />Section 1-5.4 is amended to read: <br />Section 1-5.4 All systems shall be <br />tested for leakage at 200 psi for two <br />(2) hours. <br />Installation of Sprinkler Systems in <br />Residential Occupancies. <br />UBC Section 902 amended - Stan- <br />dards of Quality <br />Section 902 1. Fire-Extinauishin>; <br />System <br />Section 902 1.-1.2 is amended to <br />read: <br />Chapter 1-General Information - <br />added <br />Section 1-5.6 is added to read: <br />Section 1-5.6 All sprinkler piping <br />shall be either non-ferrous metallic <br />pipe (copper, or brass) or CPVC. All <br />piping above the flow switch should <br />be protected by wall board or ply- <br />700-5 (Pleasanton April 2001) <br />