My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.08.045 <br />the Uniform Building Code, 1997 Edi- <br />tion, is amended to read as follows: <br />Standards. Fire-extinguishing sys- <br />tems shall comply with City of <br />Pleasanton Sprinkler Standard 9-3 <br />(NFPA 13D 1999 Edition) for on e to <br />fifteen family dwelling units (not <br />exceeding 12,000 sf in any one <br />building), and UBC Standard 9-1 for <br />all other occupancies. <br />(Ord. 1869 § 2, 2002; Ord. 1806 § 2, <br />2000; Ord. 1778 § 2, 1999; Ord. 1 669 <br />§ 2, 1995 ) <br />20.08.046 Section 1703 First <br />Paragraph Only <br />Amended - <br />Nondestructive Testing: <br />Section 1703 of the California Build- <br />ing Standards Code 2001 Edition (24 <br />CCR), and including by reference the <br />Uniform Building Code, 1997 edition, <br />is amended to read as follows: <br />1703. In Seismic Zones 3 and 4, and <br />in buildings in Seismic Zone No. 2 <br />with an importance factor I greater <br />than 1.0, all complete-joint-penetra- <br />tion groove and partial-joint-penetra- <br />tion groove welded joints in Special, <br />Ordinary and Special Truss Moment <br />Frames; in Special and Ordinary <br />Concentrically Braced Frames, and in <br />Eccentrically Braced Frames that are <br />subject to net tensile forces as part of <br />the Lateral Force Resisting System <br />shall be tested in accordance with <br />AISC Seismic Part I Section 16. This <br />testing shall be a part of the special <br />inspection requirements of Section <br />1701.5. A program for this testing <br />shall be established by the person <br />responsible for structural design and <br />as shown on plans and specifications. <br />(Ord. 1869 § 2, 2002; Ord. 1778 § 2, <br />1999) <br />20.08.048 Section 904.2.2 <br />Amended -Automatic Fire <br />Extinguishing Systems: <br />Section 904.2.2 of the California <br />Building Standards Code 2001 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code, 1997 Edi- <br />tion, is amended to read as follows: <br />904.2.2 An automatic fire extinguish- <br />ing system or other approved fire <br />suppression system(s) shall be in- <br />stalled as follows: <br />1. In every building where the floor <br />and basement area exceeds 8000 <br />square feet. <br />Exceptions: <br />1. Group R, Division 3 Occu- <br />pancies. <br />2. Group U, Division 1 private <br />garages of 1,000 square feet or <br />less. <br />3. Group U, Division 2 Occu- <br />pancies. <br />2. In all buildings of all occupancies <br />except Groups R 1, R3 and U occu- <br />pancies on a parcel when the build- <br />ing(s) area(s) on the parcel exceeds <br />8,000 square feet of floor area, in- <br />cluding area of basements. <br />(Pleasanton April 2003) '704 <br />
The URL can be used to link to this page
Your browser does not support the video tag.