My WebLink
|
Help
|
About
|
Sign Out
06/12/63 Tract2481 Memo
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
MINUTES
>
1960-1969
>
1963
>
06/12/63 Tract2481 Memo
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2013 10:58:31 AM
Creation date
7/9/2007 9:55:40 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
MINUTES
DOCUMENT DATE
6/10/1963
DOCUMENT NAME
06/12/63
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
4. S ecificati a ~ r i s ~. The City Engineer is authorlaed <br />to modify the City g sting Caudatd SpecifiCatloas and Details in <br />applying them Eo this ~ubdivigion in order to allow for modern materials, <br />methods and ddtign criCerffa as may be required; Soma specific modiflca- <br />tiona era ae followb3 <br />a. Specifications for sewer and water pipe shall be mddified to <br />allow newer Cype joiutal <br />b. Specifications fdr street tulma a~.gnk el~gll ~a modiE~ed to require <br />white reflectoriaed letters, block numbers and arrows on green <br />coated aluminum sheeting ae previously approved by the Planning <br />Commission and City Council. <br />c. Street structural design method shall be modified to require design <br />by the California R-Value method using a Traffic Index for each <br />street ae specified by the C1ty Engineer. <br />d. Reference shall be made to the 1960 Standard Specifications of the <br />State Division of Highways, rather than the 1954 edition, particular- <br />ly with reference to roadway materials. <br />5. Storm Drainase System - The culverts under the Mirador Drive extension <br />and the Hillvie~•r Ave.-Kottinger Ave. intersection shall be increased <br />to 72" and 66" respectively. The street cross section for hillside <br />streets shall be changed to require a roadside drainage ditch on the <br />uphill aide and all paved gutters shall be connected to pipe outside <br />of the street right-of-way. <br />6. Water Supvly and Distribution S3;etem <br />Minor changes in pipe rises shall be mode as shown on the approved <br />Tentative Map. The 6ystem ae ahoau (modified) is approved for serving <br />the development. If subsequent master planning indicates the desirabil- <br />ity of relocating or overacting the storage tank or any distribution <br />mains in order to serve other areas and effectuate a Master Water Plan, <br />the developer shall cooperate with the City in providing such changes <br />after negotiating with the City any coat differential. <br />7. Sewapip Collection ~atem - All curved sewer lines shall have a minimum <br />radius of 200 feet. <br />8. Fire Hvdranta - Fire hydrants shall be located ae shown on the approved <br />Tentative Map. <br />9. Electric Power Distribution nd Street Li htin S stems - A "modified" <br />undergroun system (P.G. & E. 'Streamlined Distribution" system) shall <br />be used on the first unit of development proposed, approximately 40 acres <br />along Kottinger Ave. with the easterly limit being Hillview Ave. Based <br />on information developed from this first installation a re-evaluation <br />vri11 be made, and the City will determine the method of installation to <br />be used for the remaining portion of this tentative map. <br />2. <br />
The URL can be used to link to this page
Your browser does not support the video tag.