My WebLink
|
Help
|
About
|
Sign Out
SR 06:155
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2006
>
SR 06:155
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2007 2:58:15 PM
Creation date
6/2/2006 10:32:24 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
6/6/2006
DESTRUCT DATE
15 Y
DOCUMENT NO
SR 06:155
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Page 2 <br />P-6748 <br /> <br />PROPOSED CONSTRUCTION <br /> <br />The Site Plan in the BGC report indicates the sile will be subdivided to create seven new lots, a water <br />tank property, a new street, and individual driveways. Grading operations will be performed to develop <br />the new street and driveways, building pads, the water tank area and rebuilding portions of a swale on Lot <br />6. <br /> <br />SITE CONDITIONS <br /> <br />The site conditions as described by the BGC report generally consist of shallow clayey soils over <br />Livermore Gravel bedrock. Thicker soils were encountered in the major swales and lower slopes. Various <br />small landslides were mapped by BGC and loose fill was encountered in the proposed building pad area <br />for Lot 7. <br /> <br />SITE OBSERVATIONS <br /> <br />During our site visit, we noted the following key areas of concern: <br /> <br />I. The apparent youthful nature of a large colluvial swale that underlies the northeastern portion of <br />Lot 6, including hummocky topography and an apparent landslide 'toe', suggests the presence of <br />a possible landslide. Minor downslope deflection of tree tnmks may be consistent with active <br />slope movement (creep). These observations are consistent with the log of test pit TP-5 that <br />shows a 'fairly sharp basal contact' with a ISO degree dip (downslope?). Although not <br />documented in adjacent test pits, the description of the basal contact and colluvial material is <br />consistent with that documented within the landslide debris exposed in TP-3 below the water tank <br />on Lot 7. <br /> <br />2. BGC notes the presence of a landslide on the south side of the proposed water tank site, exposed <br />in TP-3. The assumption is Ihat the landslide will be removed during grading for the tank (page 3, <br />BGC report). However, the stability of the colluvial swale, and colluvial deposits, downslope of <br />the landslide is not discussed by BGC. Our concern includes the presence of arrow within the <br />colluvial deposits as mapped on the Site Plan, suggesting downslope movement. Our field <br />observations confirm the presence of potentially unstable colluvial deposits within the iwo <br />landslides, and perhaps in downslope colluvial deposits on Lot 7. <br /> <br />3. We noted a small possible landslide, including a 2-ft scarp, on the northwest side of the main <br />access road below the tree marked' 110' on Lot 4 (?). This possible landslide is located across <br />Ihe ravine from the mapped questioned landslide on Lot 4. Minor cracking in the road suggests <br />that the slide may be active although it likely is not a major feature and may not pose a direct risk <br />to proposed building pads, depending on where the pads are located. <br /> <br />4. During our field reconnaissance of the site, we noted several deeply incised gullies on slopes and <br />upstream of drainages. Specifically, a small gully is located downslope of the existing house on <br />Lot 5 and at the head of a north flowing drainage on the northeasl portion of Lot 6. Although <br />minor, Ihese deeply incised features suggest that localized erosion is occurring near the heads of <br />active drainages and on steep slopes. <br /> <br />5. Landslide areas are immediately adjacent to the building pads for Lots 5 and 7. No discussion is <br />provided by BGC regarding isolating the building areas from potential upslope migration of the <br />landslides in the future. <br /> <br />ALAN KROPP <br />& ASSOCIATES, INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.