My WebLink
|
Help
|
About
|
Sign Out
PC-93-06
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
1990-1999
>
1993
>
PC-93-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2006 9:33:42 AM
Creation date
4/27/2005 1:36:44 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
1/27/1993
DOCUMENT NO
PC-93-06
DOCUMENT NAME
VTTM 6563
NOTES
CCG JOINT VENTURE
NOTES 3
SUBD INTO 295 SF LOTS, SCHOOL, PARK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Resolution No. PC-93-06 <br />Page 12 <br /> <br />30. All existing septic tanks or holding tanks shall be removed or <br />sealed, filled, and abandoned, pursuant to the requirements of <br />the Alameda County Department of Health Services. <br /> <br />31. The developer shall submit a dust control plan or procedure as <br />part of the improvement plans. <br /> <br />32. Approval of the storm drainage system shall be subject to the <br />review and approval of the city Engineer and Zone 7, as <br />applicable, that the system is adequate, connects to an <br />approved point of discharge, meets any and all applicable <br />requirements of the Alameda County Flood Control District - <br />Zone 7, meets any and all applicable requirements of the <br />Federal Emergency Management Flood Hazard Program, the <br />California Department of Fish and Game, and meets the <br />immediate and long-range requirements of this development and <br />all upstream areas intended to be drained through this <br />development. <br /> <br />33. The applicant shall construct a bus pull-out area on Stone <br />Point way by the park and school properties, the location and <br />geometrics of which shall be subject to the review and <br />approval of the City Engineer. <br /> <br />34. Flood Elevations <br /> <br />a. Top-of-curb elevations shall be equal to or higher than <br />the lao-year flood elevation for the site, the flood <br />elevation based on Zone 7' s new HEC-2 runs for the Arroyo <br />Mocho channel. <br /> <br />b. All building pad grades shall be constructed above the <br />loa-year flood elevation. The developer shall process <br />through the Federal Emergency Management Agency (FEMA) a <br />request for a Letter of Map Amendment (LOMA). The <br />developer shall provide a conditional LOMA from FEMA to <br />the city Engineer prior to recordation of the final map. <br /> <br />c. Prior to final inspection of each building, the developer <br />shall provide to the City Engineer an "Elevation <br />Certificate" (FEMA form) that the building pad and <br />finished first floor elevations are above the laO-year <br />flood elevation. Prior to the close of escrow on a lot, <br />the developer shall provide the city a LOMA from FEMA, or <br />the developer shall pay the flood insurance costs for the <br />lot until such time as the LOMA is received by the City. <br /> <br />35. street Design <br /> <br />a. The typical 25' private street section shall be revised <br />to show an 18" wide gutter, unless otherwise approved by <br />the City Engineer. <br />